English
Language : 

XAL-D324 Datasheet, PDF (22/46 Pages) List of Unclassifed Manufacturers – Contact functions and light functions with integral LED
10 to 150 A ratings
Cam switches, K10 series
positions (°)
1-pole
2-pole
3-pole
0 60
1
2
3
4
5
6
0 90 180 270
270 300 330 0 30 60 90
300 0 60
1
1
2
1
2
2
3
3
1-pole
3
4
5
6
2-pole
7
8
9
10
3-pole
11
12
4
5
6
7
8
9
10
11
12
4
1 5
6
7
8
9
10
11
12
Function
Degree of protection
front face
Conventional thermal current (Ith)
Rated insulation voltage (Ui) conforming to IEC60947-1
Number of positions
Number of poles
Dimensions of front plate (mm)
Front mounting method
By Ø 16 mm or 22 mm hole
(1) (3 circuits + “0” position).
(2) (Measurements between 3 phases and N + “0” position).
Switches
60° switching angle
Changeover switches
with “0” position
Ammeter
switches
Voltmeter
switches
2
IP 65
IP 65
IP 65
IP 65
10 A
10 A
10 A
10 A
440 V
440 V
440 V
440 V
2
2 + “0” position
3 + “0” pos. (1) 6 + “0” pos. (2)
1
2
30 x 30
3
2
3
30 x 30
3
30 x 30
3
30 x 30
3
K10 A001ACH K10 B002ACH K10 C003ACH K10 D002UCH K10F003UCH K10 F003MCH K10 F027MCH
Cam switches, K30 series
positions (°)
1-pole
2-pole
3-pole
0 60
1
2
3
4
5
6
1-pole
2-pole
0 90
1
2
3
4
5
6
7
8
300 0 60 300 0 60
300 0 60
1-pole
2-pole
3-pole
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
1
2
3
4
5
6
7
8
9
10
11
12
300 0 60
1
2
3
4
5
6
7
8
4
13
13
13
9
14
14
14
10
4-pole
15
15
16
16
15
16
11
12
5
Function
Switches Switches
Changeover Starting
Starting
Reversing
ON-OFF
with “0” position star-delta 2-speed
Degree of protection
front face
IP 40
IP 40
IP 40
IP 40
IP 40
IP 40
Conventional thermal current (Ith)
32 A
32 A
32 A
32 A
32 A
32 A
Rated insulation voltage (Ui) conforming to IEC60947-1
Number of positions
690 V
2
690 V
2
690 V
3
690 V
3
690 V
3
690 V
3
6
Number of poles
3
3
4
4
3
3
3
Dimensions of front plate (mm)
64 x 64
64 x 64
64 x 64
64 x 64
64 x 64
64 x 64
Front mounting method
Multifixing
K30 C003AP (3) K30 C003HP(3) K30 D004HP(3) K30 H004UP (3) K30 H001YP(3) K30 H004PP (3) K30 E003WP(3)
(3) To order switches with other thermal current ratings (50, 63, 115, 150 A): replace the number 30 in the reference by 50, 63, 115 or 150 respectively.
Example: a switch with a 32 A current rating, for example K30 C003AP, becomes K50 C003AP for a current rating of 50 A.
7
Rubber seals
for IP 65 degree of protection
For use with heads
References (5)*
* sold in lots of
8
Accessories for cam switches K1/K2
with 45 x 45 mm front plate
with 60 x 60 mm front plate
Ø 22 mm hole or 4 hole front mtg. Ø 22 mm hole or 4 hole front mtg.
KZ 65
KZ 66
with 45 x 45 mm front plate
multifixing
KZ 73
9
10
Other versions: please consult your Schneider Electric agency.
2/21