English
Language : 

TRC-075D Datasheet, PDF (2/3 Pages) List of Unclassifed Manufacturers – Switch Mode LED Drivers - Constant Current
AC INPUT (3*AWG18)
White (ACN)
Black (ACL)
Green (GND)
Dimming Control
(3*AWG22)
Yellow (10V)
Purple (1-10V)
Green (Gnd)
DC OUTPUT
(2*AWG18)
Red (+) / Black (-)
TRC-075 Dimming Series
SSL Solutions Faster Than The Speed Of Light®
Pg 2 of 3
Power Factor / Load
THD / Load
1.00
25%
0.95
0.90
20%
0.85
0.80
15%
0.75
0.70
120Vac
277Vac
10%
0.65
0.60
5%
0.55
0.50
50%
60%
70%
80%
Load
90%
100%
0%
50%
60%
70%
80%
Load
Lifetime / Case Temperature
135
120
105
90
75
60
45
30
15
0
30
40
50
60
70
80
90
Case Temperature (°C)
Typical Efficiency / Load
100%
95%
90%
85%
80%
120Vac
277Vac
75%
70%
60%
70%
80%
90%
Normalized Output Voltage
100%
Derating Curve
100
Derating Curve
100
80
80
60
60
40
40
20
20
0
-40 -25 -10 5 20 35 50 65 80
Ambient Temperature (°C)
0
90 120 150 180 210 240 270 300 330
Input Voltage (V)
120Vac
277Vac
90%
100%
Safety and EMC Compliance
UL/CUL
CE
UL 8750, UL923, IL1012, UL1310 Class 2
EN 61347-1, EN61347-2-13
EN 55015
Conducted emission
EN 61000-3-2 Harmonic current emissions
EN 61000-3-3 Voltage fluctuations and flicker
EN 61000-4-2 Electrostatic discharge
EN 61000-4-3 RFE Field Susceptibility test
EN 61000-4-4 Electrical Fast Transient
EN 61000-4-5 Surge Immunity Test, AC Power Line:
line to line 4 kV; line to earth 6 kV
EN 61000-4-6 Conducted Radio Frequency
EN 61000-4-8 Power Frequency Magnetic Field Test
EN 61000-4-11 Voltage Dips
EN 61547
Electromagnetic Immunity
ANSI/IEEE
C62.41-1991
Transient Protection. The line transient
shall consist of seven strikes of a 100 kHz
ring wave, 2.5 kV level, for both common
mode and differential mode.
Thomas Research Products • 1225 Bowes Rd • Elgin, IL 60123 • T 847-515-3057 • F 847-515-3047 • www.trpssl.com