Datasheet
Specifications
All specifications apply to all models unless noted otherwise.
Electrical characteristics
Bandwidth
DC to ≥120 MHz
Rise time
≤2.92 ns
Maximum DC current
30 A
Maximum RMS current
30 A
Maximum peak pulse current
50 A
Maximum bare wire voltage
150 V CAT II, (insulated wire 300 V CAT II)
Sensitivity
1 mA (on oscilloscopes that support 1 mV/div setting)
DC accuracy
±1% typical
±3% warranted
Maximum Amp-Second product 500 A*µs (in 30 A range)
Insertion impedance
1 mΩ at 10 kHz
3.5 mΩ at 100 kHz
0.08 Ω at 1 MHz
0.15 mΩ at 10 MHz
0.7 Ω at 100 MHz
0.85 Ω at 120 MHz
Signal delay
14.5 ns
Current ranges
Power requirements
5 A and 30 A
TCP0030A is powered directly by oscilloscopes with the TekVPI™ interface. Note: For best support, download and install the latest
version of the oscilloscope software from www.tek.com.
Physical characteristics
Probe head
Length
Width
Height
Maximum conductor size
Cable Length
Shipping Weight
20 cm (7.77 in)
1.6 cm (0.625 in)
3.2 cm (1.25 in)
5 mm (0.197 in)
200 cm (79 in)
1.55 kg (3.44 lb)
2 www.tektronix.com