English
Language : 

SP2503 Datasheet, PDF (2/2 Pages) List of Unclassifed Manufacturers – Thermoelectric Cooler
marlow
industries
Subsidiary of II-VI Incorporated
a global leader in thermoelectric solutions
Performance Curves
Environment: One atmosphere dry nitrogen
Hot Side Temperature: 27°C
Hot Side Temperature: 50°C
80.0
HEAT
LOAD
(WATTS)
60.0
0.00
2.50
5.00
40.0
7.50
10.0
20.0
12.5
15.0
17.5
0.0
20.0
3.0
2.0
Q=0
1.0
T=0
0.0
0.0 2.0 4.0 6.0 8.0 10.0 12.0
CURRENT (AMPS)
HEAT
80.0
LOAD
(WATTS)
0.00
60.0
2.50
5.00
7.50
40.0
10.0
12.5
20.0
15.0
17.5
20.0
0.0
4.0
3.0
2.0
Q=0
T=0
1.0
0.0
0.0 2.0 4.0 6.0 8.0 10.0 12.0
CURRENT (AMPS)
For performance information in a vacuum or with hot side temperatures other than 27°C or 50°C, consult one of our Applications
Engineers.
Installation
Recommended mounting methods: Bonding with thermal epoxy, mounting in compression with either
thermal grease or flexible graphite products. For additional information, please refer to our TEC Installation
Guide.
Operation Cautions
For maximum reliability, storage and operation below 85°C in a non-condensing environment is
recommended. To minimize thermal stress, use linear/proportional temperature control or a similar method
rather than an ON/OFF method.
Addresses
Marlow Industries, Inc.
10451 Vista Park Road
Dallas Texas 75238-1645
214-340-4900 (tel)
214-341-5212 (fax)
www.marlow.com
Marlow Industries Europe
Aberdeen House, South Road
Haywards Heath
West Sussex RH164NG UK
+44 (0)1444-443404 (tel)
+44 (0)1444-443334(fax)
Marlow Industries Japan
1-1-8-401
Uehara, Shibuya-ku
Tokyo, Japan 151-0064
+81 (3) 5454-5280 (tel)
+81 (3) 5454-5281(fax)
214-340-4900 (tel) ● 214-341-5212 (fax) ● www.marlow.com
Doc # 102-0313
Rev 2
Page 2 of 2