R15A-5-N Datasheet, PDF (2/3 Pages) List of Unclassifed Manufacturers – Built-in Inrush Current Protection Small size and light
R
R
Unit type
R15A
Ordering information
R
1
15A -5
2
3
-O
4
1Series name
2Output wattage
3Output voltage
4Optional
C :with Coating
G :Low leakage current
J :Connector type
N :with Cover
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
R15A-3
9
3V 3.0A
R15A-5
15
5V 3A
R15A-9
15.3
9V 1.7A
R15A-12
15.6
12V 1.3A
R15A-15
15
15V 1.0A
R15A-18
15.3
18V 0.85A
R15A-24
16.8
24V 0.7A
SPECIFICATIONS
MODEL
R15A-3
R15A-5
R15A-9
R15A-12
R15A-15
R15A-18
R15A-24
VOLTAGE[V]
CURRENT[A]
AC85 - 132 1f or DC110 - 170
ACIN 100V 0.37typ (Io=100%)
INPUT
FREQUENCY[Hz]
EFFICIENCY[%]
47 - 440 or DC
68typ
72typ
73typ
75typ
75typ
76typ
78typ
INRUSH CURRENT[A] ACIN 100V 20typ (Io=100%) (At cold start)
LEAKAGE CURRENT[mA] 0.5max (According to UL, CSA and DEN-AN)
VOLTAGE[V]
3
5
9
12
15
18
24
CURRENT[A]
3.0
3.0
1.7
1.3
1.0
0.85
0.7
LINE REGULATION[mV] 20max
20max
36max
48max
60max
72max
96max
LOAD REGULATION[mV] 40max
40max
100max
100max
120max
120max
150max
RIPPLE[mVp-p] 0 to +50C 80max
-10 - 0C 140max
80max
140max
120max
160max
120max
160max
120max
160max
120max
160max
120max
160max
OUTPUT RIPPLE NOISE[mVp-p] 0 to +50C 120max
-10 - 0C 160max
120max
160max
150max
180max
150max
180max
150max
180max
150max
180max
150max
180max
TEMPERATURE REGULATION[mV] 0 to +50C 50max
-10 to +50C 60max
50max
60max
90max
120max
120max
150max
150max
180max
180max
200max
240max
290max
DRIFT[mV]
*1 20max
20max
36max
48max
60max
72max
96max
START-UP TIME[ms]
100max (ACIN 85V, Io=100%)
HOLD-UP TIME[ms]
10typ (ACIN 85V, Io=100%, 0 to +50C) 20typ (ACIN 100V, Io=100%, 0 to +50C)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.6 4.5 - 5.5
8.1 - 9.9
10.8 - 13.2 13.5 - 16.5 16.2 - 19.8 21.6 - 26.4
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically (ACIN 100V)
PROTECTION OVERVOLTAGE PROTECTION 4.00V min
CIRCUIT AND OPERATING INDICATION LED (Green)
OTHERS REMOTE SENSING
Not provided
Works over 115% of rating (By zener diode clamping)
REMOTE ON/OFF
Not provided
INPUT-OUTPUT
AC2,000V 1minute, Cutoff current = 10mA max, DC500V 50MW min (At Room Temperature)
ISOLATION INPUT-FG, COVER
AC2,000V 1minute, Cutoff current = 10mA max, DC500V 50MW min (At Room Temperature)
OUTPUT-FG, COVER
AC500V 1minute, Cutoff current = 100mA max, DC500V 50MW min (At Room Temperature)
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
VIBRATION
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
SAFETY AND AGENCY APPROVALS
NOISE
REGULATIONS CONDUCTED NOISE
UL60950-1, C-UL Complies with DEN-AN
Complies with FCC-B, VCCI-B
CASE SIZE/WEIGHT
OTHERS
COOLING METHOD
30X69X84mm (WXHXD) / 200g max (without cover)
Convection
*1 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
* Avoid prolonged use under over-load.
* Series/Parallel operation with other model is not possible.
* Derating is required when operated with case cover.
A-102