English
Language : 

OM5262SA Datasheet, PDF (2/2 Pages) List of Unclassifed Manufacturers – HERMETIC JEDEC TO-254AA HIGH EFFICIENCY, CENTER-TAP HIGH VOLTAGE RECTIFIER
OM5262SA/RA/DA
ELECTRICAL CHARACTERISTICS
STATIC CHARACTERISTICS
Symbol
I
TJ = 25°C
R
TJ = 100°C
V
TJ = 25°C
F
TJ = 100°C
Test Conditions
V =V
R
RRM
I = 12A
F
Min.
Typ.
Max.
Unit
50
µA
2.5
mA
1.9
V
1.8
RECOVERY CHARACTERISTICS
Symbol
Test Conditions
t
T = 25°C
rr
J
IF = 1A, dIF/dt = -15A/µs, VR = 30V
IF = 0.5A, IR = 1A, Irr = 0.25A
Min.
Typ.
Max.
Unit
155
nS
65
TURN-OFF SWITCHING CHARACTERISTICS (Without Series Inductance)
Symbol
Test Conditions
Min.
Typ.
Max.
Unit
t
dIF/dt = -50A/µs
IRM
dIF/dt = -100A/µs
I
dIF/dt = -50A/µs
RM
dIF/dt = -100A/µs
V = 200V, I = 12A
CC
F
L 0.05µH, T = 100°C
P
J
See Figure 1
200
nS
120
7.8
A
9
TURN-OFF OVERVOLTAGE COEFFICIENT (With Series Inductance)
Symbol
Test Conditions
Min.
Typ.
Max.
Unit
C = VRP
TJ = 100°C
VCC = 200V, IF = IF(AV)
4.5
VCC
dIF/dt = -12A/µs
LP 12µH, See Figure 2
To evaluate the conduction losses use the following equations:
VF = 1.47 + 0.026 IF
P = 1.47 x IF(AV) + 0.026 IF2(RMS)
IF
DUT
LC
VCC
VF
dlF/dt
IF
DUT
LC
LP
VCC
VF
dlF/dt
IRM
VCC
VRP
VCC
tIRM
Figure 1: Turn-off switching characteristics
(without series inductance).
Figure 2: Turn-off switching characteristics
(with series inductance).
3.2
TYPICAL FORWARD VOLTAGE
100
70
50
TYPICAL REVERSE CURRENT
10
1.0
30
20
TC = 100°C
10
7.0
5.0
3.0
TC = 25°C
2.0
0.1
TC = 100°C
0.01
0.001
TC = 25°C
100
500
1000
VR, REVERSE VOLTAGE (VOLTS)
1.0
.8 1.0 1.2 1.4 1.6 1.8
VF, INSTANTANEAOUS VOLTAGE (VOLTS)
205 Crawford Street, Leominster, MA 01453 USA (508) 534-5776 FAX (508) 537-4246