English
Language : 

MR10 Datasheet, PDF (2/5 Pages) List of Unclassifed Manufacturers – DC/DC converters
DC/DC converters
MISTRAL Series MR10, MR10-T
Technical specifications according to BKJU.436610.011
Input specifications
Input voltage range/ transitional deviation, 1 sec
12 VDC 10,5…18VDC/ 10,5…18VDC
24 VDC 18…36VDC/17..37,8VDC
27 VDC 17…36VDC/17…80VDC
48 VDC 36…75VDC/36…84VDC
Input filter
P-type
Output specifications
Output voltage trimming range (for single-, dual-output execution with same
±5%
voltage)
Output voltage total instability
- for single-output execution (Inom 10 – 100%)
±4% (index “M”)
±6% (index “T”)
- for multi-output execution (Inom 10 – 100%)
±4% for out1 ±7% for out2&3 (index “M”)
±6% for out1 ±10% for out2&3 (index “T”)
- for multi-output execution with distinction voltage ≥20%
±4% for out1 ±14% for out2&3 (index “M”)
±6% for out1 ±14% for out2&3 (index “T”)
Pulsations ripple (peak-to-peak)
<2% Uout.nom.
Overload protection level**
>120% Iout.nom.
Short circuit protection level**
>150 % Iout.nom., autorepair
Overvoltage protection level**
>120 % Uout.nom.
Remote on/off
Off: 0…1,1VDC or connection of output «ON» and
«- IN», I≤5 mA
General specifications
- high working of case
– 60 °C…+85 °C (index “M”)
– 60 °C…+125 °C (index “T”)
Temperature
- storage
1 - power loss (free air convection)
– 60 °C…+85 °C (index “M”)
– 60 °C…+125 °C (index “T”)
See diagram (red, green lines)
Without power loss with radiator use (provided that Тcase. The module does not exceed the maximal value) see blue curve
Efficiency
82 %
Thermal resistance case - environment
12,5 ºС/Watt
Conversion frequency
150 kHz
Isolation
- voltage in/out: in/case: out/case: ~ 355 VDC, 50 Hz
Insulation resistance @ 500VDC
≥20 Ohm
External factors stability
- high humidity
100% @ 35°С
EMC standard EN 55022, class A
Safety standard IEC/ EN 60950
Time to failure
> 2 400 000 hours @ +25°C
Cooling
Free air convection or heat sink using
Case material
Metal
‘ All specifications are reduced for normal climatic conditions, Uin.nom, Iout.nom, if it is not specified differently.
‘‘ Parameters are help and cannot be used at long-term work, excess of the maximal target current, at work outside of a range of working temperatures,
at work of the module with target voltage over a range of adjustment
Power loss diagram (index «М»)
Power loss diagram (index «Т»)
12
10,5
9
7,5
MR10
Free air convection
coefficient of efficiency 80%
Heat sink
6
4,5
Free air convection
3
coefficient of efficiency 84%
1,5
0
- 60 - 50 - 40 - 30 - 20 - 10 0 10 20 30 40 50 60 70 80 90
ТеAмmпеbрieаnтуt рtаemокpрeуrжatаuюreщеTйamсрbе,д°ыCТокр, С
12
MR10-T
10,5
9
Free air convection
coefficient of efficiency 80%
7,5
Heat sink
6
Free air convection
4,5
coefficient of efficiency 84%
3
1,5
0
-60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120 130
AТеmмпbеieраnтtурtаemокpруeжraаюtuщrеeй Tсрaеmдыb,То°кCр, С
* The inclined site of a red and green curve specifies that the module works in a mode with maximal Тcase (index «М» +85ºС; index «Т» +125 ºС).
Output settings
№ pin
1
2
Single-output
+ IN
- IN
Dual-output
+ IN
- IN
Triple-output
+ IN
- IN
3
4
5
6
7
8
9
10
ON
- out
+ out
trim
Case
-
-
-
ON
- out 2
- out 1
+ out 1 + out 2
Case
-
-
ON
- out 3
+ out 3
- out 2
+ out 2
- out 1
+ out 1
Case
http://www.aeps-group.com
e-mail: aeps@aeps-group.com
tel/fax: +420-266-107-609
According to company politics in view of constant improvements production design the
manufacturer reserves the right to itself without the prior notification to change the contents
of present help materials.
© "Alexander Eleсtriс holding". All rights reserved. 27.03.2008
http://www.aeps-group.com
e-mail: alexdon@vmail.ru
tel/fax (4732) 519-518