English
Language : 

JC-A1A Datasheet, PDF (2/13 Pages) List of Unclassifed Manufacturers – ENGINEERING DATA SHEET
COIL CHARACTERISTICS (Vdc)
SERIES JC AND JCA
CODE
A
B
C
M
N [7] E
F
J
K
(VDC) (VDC) (VDC) (VDC) (VDC) (400 Hz) (400 Hz) (50 Thru 400 Hz) (50 Thru 400 Hz)
Nominal operating voltage
28 12 6
48
28
28
115
28
115
Maximum operating voltage
29
14.5 7.3 50
29 30
122
30
122
Maximum pickup voltage
- Cold coil at +125° C
18 9
4.5 36
18
22
90
23
95
- During high temp test at +125° C 19.8 9.9 5
38
19.8 24.4
95.4
24.6
100
Drop-out voltage (maximum)
7
4.5 2.5 14
7
10
30
10
30
Coil resistance Ω ±10% +25° C or
max coil current (Amps) at +25° C
320Ω 80Ω
20Ω 1000Ω 320Ω .240A
+20%
+10%
.040A
.100A
.024A
GENERAL CHARACTERISTICS
Temperature range
-70°C to 125°C
Minimum operating cycles (life) at rated load
50,000
Minimum operating cycles (life) at 25% rated load
200,000
Dielectric strength at sea level
- All circuits to ground and circuit to circuit
1250 Vrms
- Coil to ground
1000 Vrms
Dielectric strength at altitude 80,000 ft
500 Vrms [2]
Insulation resistance
- Initial (500 Vdc)
100 M Ω min
- After environmental tests (500 Vdc)
50 M Ω min
Sinusoidal vibration (A, D and J mounting)
0.12DA / 10 to 70 Hz
30G / 70 to 3000 Hz
Random vibration
- Applicable specification
MIL-STD-202
- Method
214
- Test condition - A, D, and J mounting
1G (0.4G2/Hz, 50 to 2000 Hz)
- Duration
15 minutes each plane
Shock (A, D and J mounting)
200G / 6 ms
Maximum contact opening time under vibration and shock
10 µs
Operate time at nominal voltage (either coil)
- Series JC
10 ms max
- Series JCA
15 ms max
Release time at nominal voltage (either coil)
- Series JC
10 ms max
- Series JCA
50 ms max
Contact make bounce at nominal voltage@25°C
1 ms max
Contact release break bounce at nominal voltage@25°C
0.1 ms max [8]
Weight maximum
0.10lb
Unless otherwise noted, the specified temperature range applies to all relay characteristics.
Date of issue: 06/10
- 147 -
Page 2 of 4