English
Language : 

H-A4A Datasheet, PDF (2/14 Pages) List of Unclassifed Manufacturers – CONTACTOR 60 AMP
COIL CHARACTERISTICS (Vdc)
CODE
Nominal operating voltage
Maximum operating voltage
Pick-up voltage, maximum
- Nominal
- High temp test
- Continuous current test
Drop-out voltage, maximum
Coil resistance in Ohms ±10% at +25° C
Coil current max. mA at +25° C
SERIES H,HD,HP,HT,HTD,HPT
A
B
C
F
N [6]
Vdc
Vdc
Vdc
Vac 400Hz Vdc
28
12
6
115
28
29
14.5
7.3
124
29
18
9
4.5
90
18
20
10
5
95
20
22.5
11
5.7
100
22.5
7
4.5
2.5
30
7
200
50
12
-
200
-
-
-
90
-
GENERAL CHARACTERISTICS
Temperature range
Minimum operating cycles (life) at rated resistive load
Minimum operating cycles (life) at 25% rated resistive load
Dielectric strength at sea level
- All circuits to ground and circuit to circuit
- Coil to ground and aux. contacts
Dielectric strength at altitude: 15,240 m
- Main contacts
- Coil and aux. contacts
Insulation resistance
- Initial
- After environmental tests
Sinusoidal vibration
Shock (6 ms duration)
Maximum contact opening time under vibration and shock
Operate time at nominal voltage (Including bounce)
Release time at nominal voltage (Including bounce)
- DC
- AC
Contact bounce at nominal voltage
Weight
Power requirements:
- at pick-up +25° C
- at nominal D.C. voltage
Overload @ 115/200 Vac, 400Hz.
@ 28 Vdc
Rupture @ 115/200 Vac, 400Hz.
@ 28 Vdc
-55°C to +71°C
50,000
200,000
1500 Vrms
1000 Vrms
700 Vrms
500 Vrms
100 M Ω min
50 M Ω min
10 G / 70 to 2000 Hz
50 G
10 µs
50 ms max
35 ms max. [5]
25 ms max
80 ms max
3 ms max
400 grams max.
330 grams max. [5]
0.980 watt
4.35 watt max.
400 Amp
125 Amp
500 Amp
150 Amp
Date of issue: 01/11
- 61 -
Page 2 of 5