INPUT SPECIFICATIONS (1)
Description
Input Voltage Range (3)
Minimum Turn-On Voltage
Drop out Voltage
Maximum Input Current
Minimum input current (for on-state)
Input Resistance
Turn-on time (4)
Turn-off time
Min/Max stranded/solid wire
GENERAL SPECIFICATIONS
GNRxxDx
4-32 VDC
4.0 VDC
1.0 VDC
19mA
16mA
Current Regulated
8.33ms
8.33ms
24/16AWG
Description
Ambient Operating Temperature Range (3)
Ambient Storage Temperature Range
Input to output isolation
Input/output to ground isolation
Input to output capacitance
Housing Material
Status Indicating Display
Weight (typical)
Parameters
-20 to 80 °C
-40 to 100 °C
4000 Vrms
2500 Vrms
8 pF
UL 94V0 (self extinguishing)
Green LED
0.5lbs (225 g)
GENERAL NOTES
1) All parameters at 25°C unless otherwise specifie d.
2) Off-State dv/dt test method per EIA/NARM standard RS-433, paragraph 13.11.1
3) For 180-280VAC control, maximum Ambient operating temperature is 60°C
4) Random turn-on time R suffix is 100µs (for DC control only).
GNRxxBx
90-140VAC
90 Vrms
10 Vrms
23mArms
6mArms
Current Regulated
20ms
30ms
24/16AWG
GNRxxAx
180-280VAC
180Vrms
10 Vrms
23mArms
8mArms
Current Regulated
20ms
30ms
24/16AWG