G38910052230 Datasheet, PDF (2/5 Pages) List of Unclassifed Manufacturers – Ethernet Modbus/TCP Gateway
G 3891 0052
Du line®
Fieldbus Installationbus
General Specifications
Supply Specifications
Power ON delay
Indication for
Supply ON
Dupline® carrier
Fault
Ethernet Link
Ethernet Module Status
Ethernet Activity
Environment
Degree of protection
Pollution degree
Operating temperature
Storage temperature
Humidity (non-condensing)
Mechanical resistance
Shock
Vibration
Dimensions
Material
Weight
< 2.5 s until start of
Dupline® carrier.
< 40 s until correct reading
of AnaLink values
LED, green
LED, yellow
LED, red
LED, green
LED, green/red
LED, green
IP 20
3 (IEC 60664)
0° to +50°C (+32° to +122°F)
-20° to +85°C (-4° to +185°F)
20 to 80% RH
Power supply
Overvoltage cat. III (IEC 60664)
Rated operational voltage
through term. 21, 22, 23 & 24 See wiring diagram
230 230 VAC ± 15% (IEC 60038)
115 115 VAC ± 15% (IEC 60038)
Frequency
45 to 65 Hz
Rated operational power
11 VA
Rated impulse withstand
voltage
230 4 kV
115 2.5 kV
Dielectric voltage
Supply - Dupline®
≥ 4 kVAC (rms)
Supply - RS 485
≥ 4 kVAC (rms)
15 G (11 ms)
2 G (6 to 55 Hz)
H8-housing
(see Technical information)
540 g
Wiring Diagrams
Power supply
230 VAC
Power supply
115 VAC
DUPLINE D+
D
123456789
DUPLINE
SETTINGS
ON
NO.
CHANNELS
ETHERNET CONNECTOR
1 234
10 11 12 13 14 15 16
IP ADDRESS
LEDS STATUS
12
43
21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36
115V 115V
P
NP
N
SUPPLY
Mode of Operation
The Dupline® Ethernet Gate-
way is a Dupline® Channel Gen-
erator with the function of a
Modbus/TCP slave.
This
means that the 128 Dupline®
I/O’s can be read/controlled by
Modbus/TCP masters like
PLC’s and PC interface cards
from many different suppliers.
Several Dupline® Gateways can
be connected to the same net-
work and operate together with
other Ethernet modules like
operator panels, MMI’s I/O
modules etc.
Dupline Configuration
switches
The unit is equipped with the
following Dupline configuration
switches. (See also switch set-
tings)
2
1x16 position rotary-switch for
selecting Number of Dupline®
Channels in the range 8..128 (in
steps of 8). The selected letter
indicates the last channel group
available on Dupline®. If e.g. H
is selected, the 64 channels in
groups A..H will be available.
DIP-switch (1) for selection of
Dupline® Operation Mode. In
"Normal" mode, Dupline® oper-
ates as a peer-to-peer system
where the channel generator
automatically establishes a
connection between Dupline®
inputs and Dupline® outputs
which are coded to the same
Dupline® address. If e.g. an
input coded for B5 is activated,
the output(s) coded for B5 will
also be activated. Consequent-
ly a Dupline® output can either
be activated through the out-
put-data received on Ethernet
or by an active Dupline® input
coded for the same Dupline®
address. In "Split I/O" mode,
the Dupline® inputs and
Dupline® outputs are created
independently by the channel
generator. If e.g. and input cod-
ed for B5 is activated, the
Gateway will make the informa-
tion available on Ethernet (like
in normal mode), but it will not
automatically activate the
Dupline® output(s) coded to B5.
The Dupline® outputs are con-
trolled exclusively through the
output data received on Ether-
net.
Note: Analink output as well as
BCD multiplex data only work
in split I/O mode.
DIP-switch (2) for selection of
analog data. In OFF position
only Digital In/Out data are
transferred. To enable analog
data-I/O handling this DIP-
switch must be ON.
DIP-switch (3) for selection of
Analog input operation mode.
When OFF the analog input
data are read as AnaLink. Each
channel from C1 to P8 is read
as 8 bit analog data. When ON
the analog input data are con-
sidered as 3 _ digit BCD multi-
plexed data. The multiplex-con-
trol (Synchronization) are auto-
matically set to operate on
channels A1..A4, which then
cannot be used for other pur-
poses.
Specifications are subject to change without notice (21.08.2006)
Dupline® is a registered trademark. A product of the CARLO GAVAZZI Group