English
Language : 

F11-E06 Datasheet, PDF (2/2 Pages) List of Unclassifed Manufacturers – Encapsulated Thermostats for Electronics
Type
Voltage Rating 50-60 Hz
Current rating
RESISTIVE
INDUCTIVE
max. load RES.
short circuit current upto
Contact Arrangment Normally closed N/C
Normally open N/O
Contact resistance
Response temperature range
Tolerance (minimum range)
Max. permanent temperature - Housing
Switch mechanism
N/C
120 V / 250 V
3.0 A / 2.0 A
1.8A / 1.2 A
4.0 A
6.3 A
< 40 mΩ
70ºC to 160ºC
+/- 15ºC, +/-10ºC,
+/-5ºC
220ºC **
175ºC
N/O
120 V / 250 V
1A/1A*
1A/1A
4.0 A
6.3 A
< 40 mΩ
+65ºC to +150ºC
+/- 15ºC, +/-10ºC,
+/-5ºC
220ºC **
175ºC
F11-E06-PC
CURRENT SENSIVITY
The thermostats are not current sensitive at rated
currents. At loads above the rated values, up to
maximum loading there is self-heating of the current
carrying contacts.
* When N/0 contacts are closed, self heating will
occur at currents exceeding normal rating. It is
possible that, given certain combinations of set
temperature current & ambient temperature, the
contacts will not reset.
** Wire insulation must be appropriate
F11-E06
INSULATION RESISTANCE
Leads to Earth
2500 V @ 25°C
1500 V @ 100°C
On request
(Requires special testing)
up to 4000 V eff. AC @ 200°C
Across open contacts,
dependent on response
temperature
500 V eff. AC
RESPONSE TEMPERATURES,
TOLERANCE
Temperature stepped in 5°C increments. Special
switch-off and reset temperatures available on
request. Rate of temperature rise from 0.1° C/min.
to max. 1.0° C/min. Insulation of the housing will
slow down the cutout’s response.
QUALITY ASSURANCE
Housing material - PPS (UL 94 V-0)
Contacts - Silver plated
MTBF - 10,000 cycles at rated current and voltage
Minimum switching current 50ma
Random sample quality testing
Function test to AQL 1.0
Nominal response temperature AQL 1.0
Measurement tolerance ±2°C AQL 4.0
Other values AQL 4.0
Thermal conductivity - 4.0 BTU In/hr/Ft2/ºF
ORDERING INFORMATION
Quantity
100
Type
F11
Response Version Tolerance
Temp. N/O or N/C +/- 5ºC
125º
1 or 2
5
We reserve the right to change specifications without
prior notice. ADD - PC to part number for PC lead
frame leads.
Typical PC P/N = F11125253600060
With Leads P/N = F1112525ACFA06E
UL E46827
VDE 4523-4510-1015
It is the responsibility of the
customer to insure that the
devices descibed above are
used in a safe manner and
within published parameters.
CT-M-ENG-03B-1