English
Language : 

E11 Datasheet, PDF (2/4 Pages) List of Unclassifed Manufacturers – Thermal Cutouts Temperature Protection for Electronics
APPLICATIONS
Temperature monitoring, control and signalling in
electronic and electrical equipment.
Examples:
Electronic components such as transistors,
thyristors, diodes, triacs
Power resistors
Heat sinks
Printed circuits
Amplifiers
Projectors
Electrical machinery and apparatus
Generating sets
Heat exchangers
Plastic and metal housings
RESPONSE TEMPERATURES
When selecting the response temperature, the hea-
ting and cooling characteristics of the housing
should be considered. Temperature testing is carried
out with a rate of rise 0.1 °C/min.
For cutout types E 05, E 11 and E 18 with response
temperatures under 71 °C, the published electrical
loading should be reduced by upto 50 %, as these
types are current sensitive.
Close tolerances on the response temperature or
reset temperature, as well as smaller differentials
are all possible on request.
Reset differential as standard is between 10 °C and
50 °C. Minimum rate of temperature change 0.1
K/min.
TECHNICAL DATA
Type
Voltage rating* 50 – 60 Hz*
Current rating cos ϕ = 1,0*
Current rating cos ϕ = 0,6*
Max. load
at cos ϕ = 1,0
without damage 250 V AC
110 V AC
60 V DC
42 V DC
6/12/24 V DC
Contact arrangement
Switching operations
at rated current*
Contact resistance
Dielectric strength
across open contacts
Response temperature range
Standard tolerance
Dielectric strength
housing to earth
Max. continuous temperature
Possible acceleration
Protection
Connections
standard
Switch element
E 05 / E23
250 V
2.0 A
1.2 A
3.0 A
3.5 A
0.6 A
0.8 A
1.0 A
E 15 / E 16
250 V
2.0 A
1.6 A
6.3 A
8.0 A
1.0 A
1.2 A
1.5 A
E 11 / E 18 / E 21 / E 22 / E 26
250 V
6.3 A
4.0 A
10.0 A
12.0 A
3.0 A
4.2 A
5.5 A
Test Class I
Test Class I
Test Class I
< 60 mΩ
< 60 mΩ
< 60 mΩ
650 Veff 50 Hz
1500 Veff 50 Hz
1000 Veff 50 Hz
from +80 °C to
+150 °C
(353 to 423 K)
from +50 °C to
+150 °C
(323 to 423 K)
from +50 °C to
+150 °C
(323 to 423 K)
±3 K ±5 K ±10 K
±3 K ±5 K ±10 K
P 300 500 V eff 50/60 Hz
P 301 1000 V eff 50/60 Hz
P 302 2000 V eff 50/60 Hz
P 303 2500 V eff 50/60 Hz
P 304 4000 V eff 50/60 Hz
±3 K ±5 K ±10 K
150 °C
3 g (vibration proof)
sealed against external elements e. g. dust oil, lacquer, resin et
Leads
0,25 mm2 (AWG 24)
black
Leads
T 11 normally closed 0.5 mm2 (AWG 22), yellow
T 10 normally open 0.25 mm2 (AWG 24), black
Leads
0,6 mm2 (AWG 22)
yellow
F 11
normally closed T 11 / normally open T 10
B11
Note: *Approved ratings – Other values on request.
INSTALLATION HINTS
It is important to ensure good heat transfer to the cu-
tout: it should be placed directly onto the heat sour-
ce.
Housings are voltage-free (except G 800) and can
be installed without additional insulation.
The cutouts can be attached to metal surfaces or
housings and, depending on the exact version, can
be screwed, clipped, clamed or soldered on.
G 800 version can be positioned direct onto a circuit
board.