English
Language : 

DT6-6 Datasheet, PDF (2/2 Pages) List of Unclassifed Manufacturers – Thermoelectric Cooler
Thermoelectric Cooler
DT6-6
Performance Curves
Environment: One atmosphere dry nitrogen
Hot Side Temperature: 27°C
Hot Side Temperature: 50°C
80.0
HEAT
LOAD
(WATTS)
80.0
HEAT
LOAD
(WATTS)
60.0
40.0
20.0
0.0
0.00
2.50
5.00
60.0
7.50
10.0
12.5
15.0
40.0
17.5
20.0
22.5
20.0
25.0
27.5
0.00
2.50
5.00
7.50
10.0
12.5
15.0
17.5
20.0
22.5
25.0
27.5
0.0
30.0
8.0
10.0
6.0
8.0
4.0
Q=0
T=0
2.0
0.0
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0
CURRENT (AMPS)
6.0
4.0
Q=0
2.0
T=0
0.0
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0
CURRENT (AMPS)
For performance information in a vacuum or with hot side temperatures other than 27°C or 50°C, consult one of our
Applications Engineers.
Installation
Consult Marlow Industries’ Thermoelectric Installation Guide or reliability report for more details. For additional
information, please contact one of our application engineers for technical support.
Operation Cautions
Maximum storage and operation +150°C.
For maximum reliability, storage and operation below 85°C is recommended. Excessive power cycling and powering
through thermostatic (on/off) control is not recommended.
Marlow Industries, Inc.
10451 Vista Park Road
Dallas Texas 75238-1645
TEL: 214-340-4900
FAX: 214-341-5212
Internet: www.marlow.com
Marlow Industries Europe
Aberdeen House, South Road
Haywards Heath
West Sussex RH164NG UK
TEL: +44 (0)1444-443404
FAX: +44 (0)1444-443334
Marlow Industries Asia
1-1-8-401
Uehara, Shibuya-ku
Tokyo, Japan 151-0064
TEL: +81 (3) 5454-5280
FAX: +81 (3) 5454-5281
Copyright 2000, Marlow Industries, Inc. Marlow Industries reserves the right to change the design and specifications of products without notice. 102-0154, Rev E