Specifications
CFM150M Series Derating Curve
INPUT SPECIFICATIONS:
Voltage …....………........…........................................... 90~264Vac
Frequency ………………………………………….……………..... 47 to 63Hz
Inrush Current ………………….……………................. 110A max. @240Vac
Leakage Current ………………………………………….…...…… 300uA max.
OUTPUT SPECIFICATIONS:
Holdup Time …………………………………………………………... 16ms typ.
Short Circuit Protection ……….…….………… Hiccup mode(Auto Recovery)
Adjustment Range on Vout ………………………………………………. ±5%
Over Voltage Protection ………………………… Recycle AC input to restart
Temperature Coefficient ……………………..............................… ±0.05%/℃
GENERAL SPECIFICATIONS:
Isolation ………………………………….……… Input to output = 5,656VDC
Operating Temperature .......................... -20℃~ 70℃ (see Derating Curve)
Storage Temperature ……………….…………….........……........ -20 ~ 85℃
Humidity ....................................................... 93% RH max. Non condensing
Cooling ……………………………………………………. Natural Convection
Switching Frequency ………………………............................ 90KHz Typical.
MTBF ………….… MIL-HDBK-217F, GB, 25℃/115VAC …… 100K hrs min.
Altitude ……………………..………………...………………………….. 3000m
Dimensions ………….. 5.000x3.000x1.050inches (127.00x76.20x26.67mm)
Weight ………………………………………………………... 270g (0.6Pounds)
SAFETY AND EMC:
Emission and Immunity …….… EN55011 Class B, FCC Part 15 Class B
EN60601-1-2, EN61000-3-2 Class A, B, C, D, EN61000-3-3
Safety ………………..……..IEC60601-1, EN60601-1, UL60601-1
CFM150M Series
All Dimensions are in inches[mm]
Tolerances: Inches:x.xxx=±0.02
Millimeters:x.xx=±0.5
5.000[127.00]
0.224[5.70]
4.546[115.48]
10 0%
8 0%
6 0%
4 0%
20 LFM(Natural C onve cti on)
2 0%
0%
-20 -10 0 10 20 30 40 50 60 70
Ambient Temperature(oC)
NOTE:
1. CFM150M:Add a 0.1uF ceramic capacitor and 10uF E.L.
capacitor to output for Ripple & Noise measuring @20MHz BW.
2. Line regulation is measured from High Line to Low Line with full load.
3. Load regulation is measured from Full to 10% load.
4. Connectors: AC input: Molex 5277 or equivalent
DC output: Molex 5273 or equivalent
5. DC output pin 1, 2, 3, 4: Vout (-), DC output pin 5, 6, 7, 8: Vout (+)
Typical at 25˚C, nominal line and 75% load, unless otherwise Specified
2