English
Language : 

BCM-5-306-150-00-21X Datasheet, PDF (2/2 Pages) List of Unclassifed Manufacturers – Charges Nickel Metal Hydride Batteries
BCM NiMH
WIDE RANGE BATTERY CHARGERS
Input
Voltage
Line Frequency
Current
Protection
Electrical
Topology
Dielectric Withstand
EMI
CE
MTBF
Protection
Safety Approvals
Agency Listings
100 - 250 VAC -10%, +6%
47 - 63 Hz
0.5 max at 120 VAC input
Internal primary current fuse
Inrush limiting
Short Circuit Protection
Environmental
Operating Temperature
Storage Temperature
Relative Humidity
Altitude
Cooling
0º – 50º C with no derating
-30º to +85º C
5% to 95% non-condensing
0-10,000 feet
0-10,000 feet
Convectional - non vented case
Switching - DC battery charger
3000 VAC, 4242 VDC primary - secondary
Complies with EMC Directives
CE Compliant
100,000 calculated hours
Output current limiting,
Short circuit protection
Mechanical
Case and Dimensions
Case Material
Weight
Cords and Connectors
4.22L x 2.60W x 1.51H (in)
107.2L x 66.04W x 38.35H (mm)
94V0 polycarbonate; black is standard
color; other colors available - extra
charges may apply
8 ounces, 210 grams (excluding cord)
6 ft., 3 conductor, 18 AWG, Ault #21
connector (thermistor is in pack). Other
connectors are also available.
cULus 60950; TUV EN60950
Safety Timer Codes (*from pg. 1)
5 = 1.5 hours
6 = 3.0 hours
7 = 6.0 hours
8 = 9.0 hours
Please specify the Safety Timer Code in your order.
Input Configuration
IEC320
w/ground
C14
(F)
Configuration: In Case IEC320 with ground
Connector
Pinout Code
Battery (+): 1, Thermister: 2, Battery (-): 3
Description
3-pin overmolded Molex connector
Housing 26-03-4041
Terminals 08-50-0187
Suggested Mating
0.045 square pin on 0.156 centers.
(Ref: Molex Seroes 2220, 5273, 5274)
Other Connectors are available by special order
AULT INCORPORATED
7105 Northland Terrace | Minneapolis, Minnesota 55428 | USATEL (1) 763-592-1900
FAX (1) 763-592-1911 | E-MAIL info@aultinc.com | WEB www.aultinc.com
© Copyright 2002 Ault Inc.