B108024006 Datasheet, PDF (2/3 Pages) List of Unclassifed Manufacturers – Timers Interval
B 108, B 208, B 101, B 201
Output Specifications
B 108, B 101
B 208, B 201
Output
Basic electrical insulation
SPDT relay
250 VAC (rms) (contact/electronics)
Contact ratings (AgCdO)
µ (micro gap)
Resistive loads
AC 1 10 A/250 VAC (2500 VA)
DC 1 1 A/250 VDC (250 W)
or 10 A/25 VDC (250 W)
Small inductive loads AC 15 2.5 A/230 VAC
DC 13 5 A/24 VDC
Mechanical life
≥ 30 x 106 operations
Electrical life
AC 1 ≥ 2.5 x 105 operations (at max. load)
Operating frequency
≤ 7200 operations/h
Insulation voltages
Rated insulation voltage
≥ 2.0 kVAC (rms) (contact/electronics)
Rated transient protection volt. 4 kV (1.2/50 µs) (contact/electronics) (IEC 60664)
DPDT relay
250 VAC (rms) (contacts/elec., contact/contact)
µ (micro gap)
8 A/250 VAC (2000 VA)
0.4 A/250 VDC (100 W)
4 A/25 VDC (100 W)
2.5 A/230 VAC
5 A/24 VDC
≥ 30 x 106 operations
≥ 2.5 x 105 operations (at max. load)
≤ 7200 operations/h
≥ 2.0 kVAC (rms) (contact/electronics)
4 kV (1.2/50 µs) (contact/electronics) (IEC 60664)
Supply Specifications
General Specifications
Power supply AC types
Rated operational voltage
through pins 2 & 10
220
or pins 2 & 7
120
024
Drop-out tolerance
Rated insulation voltage
Rated transient protection volt.
Power supply DC type
Rated operational voltage 024
Rated insulation voltage
Rated transient protection volt.
Consumption
AC supply
DC supply
Installation cat. III
220 VAC + 15/- 20%,
45 to 65 Hz
120 VAC + 15/- 20%,
45 to 65 Hz
24 VAC + 15/- 20%,
45 to 65 Hz
≥ 10 ms
None
4 kV (1.2/50 µs) @ 220 VAC
2.5 kV (1.2/50 µs) @ 120 VAC
800 V (1.2/50 µs) @ 24 VAC
(line/neutral)
Installation cat. III
24 VDC + 15/- 20% (pin 2 pos.)
None
800 V (1.2/50 µs)
60 mA @ 50 Hz/70 mA @ 60 Hz
1W
Power ON delay
Power OFF delay
Indication for
Output ON
Environment
Pollution degree
Operating temperature
Storage temperature
Weight
Approvals
≤ 200 ms
≥ 250 ms
LED. red
IP 20 B
2 (IEC 60664)
-20° to +50°C (-4° to +122°F)
-50° to +85°C (-58° to +185°F)
85 g
UL, CSA
Mode of Operation
Wiring Diagrams
The relay operates and the ti-
me period starts when power
supply is applied to the time
relay.
At the end of the set delay,
the relay releases and will not
operate again until power
supply is reapplied.
A recovery period of 250 ms
should be allowed before re-
applying power supply.
If power supply is interrupted
for more than 250 ms before
the time period has expired,
the relay releases and the time
is reset to zero.
Power supply
B 108, B 208
Power supply
B 101, B 201
2