English
Language : 

8267 Datasheet, PDF (2/3 Pages) List of Unclassifed Manufacturers – 13 AWG stranded (7x21) .089 bare copper conductor, polyethylene insulation
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
EU Directive 2003/11/EC (BFR):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
Military Specification:
RG Type:
Flame Test
UL Flame Test:
Plenum/Non-Plenum
Plenum (Y/N):
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm)
50
Nom. Inductance:
Inductance (µH/m)
0.252637
Nom. Capacitance Conductor to Shield:
Capacitance (pF/m)
101.055
Nominal Velocity of Propagation:
VP (%)
66
Nominal Delay:
Delay (ns/m)
5.05274
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
5.5777
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/km)
3.9372
Nom. Attenuation:
Freq. (MHz) Attenuation (dB/100m)
1
0.88587
10
1.80455
50
4.2653
100
6.2339
200
8.8587
400
13.4521
700
21.3265
900
24.9356
1000
26.248
4000
70.5415
Max. Power Rating:
Freq. (MHz) Rating (W)
1
7950
10
2761
50
1122
100
748
200
494
400
326
700
235
Yes
Yes
Yes
MIL-DTL-17H, M17/74-00001
213/U
VW-1
No
Page 2 of 3
8267 Coax - 50 Ohm Cable
05-10-2011