English
Language : 

71-108221-2 Datasheet, PDF (2/3 Pages) List of Unclassifed Manufacturers – High current capacity control
TYPE 70/71 PART NUMBERING SYSTEM
7x – x xx x x x - x
Basic Part
Number Series
Type 71 case is
approx. 0.29” longer
than Type 70
Contact
Form
1 – SPNO
3 – SPDT
Coil
Voltage/Duty
08 – 6 Volt continuous
09 – 6 Volt intermittent
11 – 12 Volt continuous
12 – 12 Volt intermittent
14 – 18 Volt continuous
15 – 18 Volt intermittent
17 – 24 Volt continuous
18 – 24 Volt intermittent
20 – 36 Volt continuous
21 – 36 Volt intermittent
Coil Termination
(15 in-lb torque spec.)
221 – Isolated coil, all Ag contacts
222 – Coil terminal with ground
wire, all Ag contacts
224 – Isolated coil, Cu NO
and Ag NC contacts
225 – Coil terminal with ground
wire, Cu NO and Ag NC
contacts
226 – Coil common to NO (stud
marked “BAT”), Cu NO
and Ag NC contacts
Not all part number combinations are released. Please contact your Sales Representative for
a list of active part numbers.
APPLICATION NOTES
Factory Assigned Specials
(where undefined, contact factory)
2 – Hardware loosely
assembled
2B – Customer requested
markings
2C – Customer requested
markings
3 – Customer requested
markings
4 – Customer requested
markings
5 – Hardware bulk packed
5C – Customer requested
markings
5F – Customer requested
markings
7 – No hardware included
• A back-up wrench MUST be used to hold the bottom nut stationary during installation.
• Solenoids applied in battery charging circuits should be protected from higher than rated voltage during charging. The
service life may be affected by this condition and the solenoid may or may not operate the circuit as intended.
• Circuits should be designed to provide safe operation should the solenoid fail in either the open or closed position.
• Special construction options, including a curved bracket, may be available under other part numbers, including111-
xxxD (short can), 111-xxxE (long can), 5608-x and 878x-x.
SPNO – Isolated Coil
.281 WIDE X .390 LONG SLOT
5/16–UNF–2A
.485 (USABLE)
LENGTH
Coil Terminal to Ground
.281 WIDE X .390 LONG SLOT
5/16–UNF–2A
.485 (USABLE)
LENGTH
#10-32 UNF-2A X .470
W 3.480
2.109
COIL CONNECTION
(ISOLATED)
0.900
(Type 70)
.569
1.196
(Type 71)
L
2.429 (Type 70)
2.725 (Type 71)
#10-32 UNF-2A X .470
CIRCUIT DIAGRAM
GROUND
WIRE
W 3.480
2.109
COIL CONNECTION
WITH GROUND WIRE
.248
1.082
H
2.400
0.900
(Type 70)
.569
1.196
(Type 71)
L
2.429 (Type 70)
2.725 (Type 71)
CIRCUIT DIAGRAM
.248
H
2.400
1.082
Coil Common to Load
.281 WIDE X .390 LONG SLOT
COMMON
TERMINAL
5/16–UNF–2A
.485 (USABLE)
LENGTH
SPDT – Isolated Coil
.281 WIDE X .390 LONG SLOT
5/16–UNF–2A
.485 (USABLE)
LENGTH
.248
W 3.480
2.109
COIL CONNECTION
(COMMON)
0.900
(Type 70)
.569
1.196
(Type 71)
L
2.429 (Type 70)
2.725 (Type 71)
#10–32 UNF–2A
.470 LONG
CIRCUIT DIAGRAM
2.109
W
3.480
#10–32 UNF–2A
.470 LONG
.248
1.082
H
2.400
0.900
(Type 70)
1.196
(Type 71)
.569
L
3.313 (Type 70)
3.609 (Type 71)
COIL CONNECTION
(COMMON)
1.082
H
2.400
CIRCUIT DIAGRAM
R-4003C
1233