English
Language : 

2413 Datasheet, PDF (2/5 Pages) KR Electronics, Inc. – Bandpass Filter
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
2413 Multi-Conductor - Enhanced Category 6 Nonbonded-Pair Cables
Installation Temperature Range:
Operating Temperature Range:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius/Minor Axis:
Min. Bend/Installation:
+5°C To +50°C
0°C To +75°C
40.181 Kg/Km
177.928 N
19.050 mm
57.150 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
CMP
CEC/C(UL) Specification:
CMP
EU Directive 2011/65/EU (ROHS II):
Yes
Other Standards:
ISO/IEC 11801 ed 2.1 (2008) Class E
EU CE Mark:
Yes
EU Directive 2000/53/EC (ELV):
Yes
EU Directive 2002/95/EC (RoHS):
Yes
EU RoHS Compliance Date (mm/dd/yyyy):
10/13/2005
EU Directive 2002/96/EC (WEEE):
Yes
EU Directive 2003/11/EC (BFR):
Yes
CA Prop 65 (CJ for Wire & Cable):
Yes
MII Order #39 (China RoHS):
Yes
Telecommunications Standards:
Applicable Patents:
Country Patent
US
5563377
US
6570095
US
6998537
US
7179999
CANADA 2144694
US
7977575
Category 6 - TIA 568.C.2
Flame Test
UL Flame Test:
C(UL) Flame Test:
CSA Flame Test:
Suitability
Suitability - Indoor:
Suitability - Outdoor:
Plenum/Non-Plenum
Plenum (Y/N):
Non-Plenum Number:
NFPA 262 Plenum Flame Test (UL910)(FT6)
FT6
FT6
Yes
No
Yes
2412
Electrical Characteristics (Overall)
Nom. Mutual Capacitance:
Capacitance (pF/m)
49.215
Maximum Capacitance Unbalance:
Capacitance (pF/m)
1082.730
Page 2 of 5