English
Language : 

HP203B Datasheet, PDF (16/18 Pages) List of Unclassifed Manufacturers – PRECISION BAROMETER AND ALTIMETER SENSOR
DataSheet
HP203B
will not be changed by this command.
The SOFT_RST will clear all the interrupts as well as the related register bits.
The interrupts are cleared once the device has confirmed a valid command is received. However, this
does not necessarily mean that an interrupt must go low after a command is fully transmitted. For
example, while an interrupt is being cleared by an ADC reading command, it goes low while the data is
being sent back from the device to the external MCU.
6.4 Enable the Compensation
PARA - (RW)
This register has only one valid bit of CMPS_EN. The user can use this bit to determine whether to
enable the data compensation during the conversion process (0: disable, 1: enable). If it is enabled,
the 24-bit or 48-bit data read out by the commands are fully compensated. If it is disabled, the data
read out are the raw data output.
7. Typical Application Circuit
Figure3: Typical application circuit
HP203B_DataSheet_EN_V2.0
www.hoperf.com
16 / 18