English
Language : 

REBEL-STAR-CW100 Datasheet, PDF (15/26 Pages) List of Unclassifed Manufacturers – LUXEON® Rebel General Purpose White Portfolio
Current Derating Curves
Current Derating Curve for 350 mA Drive Current
Cool-White and Neutral-White
400
350
300
250
15°C/W
200
25°C/W
150
35°C/W
100
45°C/W
50
0
0
25
50
75
100
125
150
175
TA - Ambient Temperature (°C)
Figure 8. Maximum forward current vs. ambient temperature, based on TJMAX = 150ºC.
Current Derating Curve for 700 mA Drive Current
Cool-White and Neutral-White
800
700
600
500
400
15°C/W
300
25°C/W
35°C/W
200
100
0
0
25
50
75
100
125
150
175
TA - Ambient Temperature (°C)
Figure 9. Maximum forward current vs. ambient temperature, based on TJMAX = 150ºC.
1. Current derating curves represent constant current operation condition.
LUXEON Rebel General Purpose Datasheet DS64 20121212
15