English
Language : 

PBA150F-12-N Datasheet, PDF (14/14 Pages) List of Unclassifed Manufacturers – AC-DC Power Supplies Enclosed type
Block diagram
AC IN 85 - 264V
FG
FUSE
250V4A
NOISE
FILTER
RECTIFIER
INRUSH
CURRENT
LIMIT
BOOSTER
INDUCTER
CURRENT
SENSING
RECTIFIER
AND
FILTER
INVERTER
CONTROL
CURRENT
SENSING
CONTROL
INVERTER
TRANSFORMER
PBA150F
PBA/PBW
OPTION
CONTROL
OVER VOLTAGE
PROTECTION
RECTIFIER
AND
FILTER
RC
EXTERNAL E
SOURCE
DC OUT
External view
¶ External size of option T,J,R,N,N1,V and K is different from standard model and refer to 7 Option of instruction manual for details.
CN3
Connector for Remote ON/OFF (option)
(20.5)
[0.81]
Voltage adjust (11.5)
[0.45]
LED
(13.5)
[0.53]
12
CN4
Connector for Remote sensing (option : only -3R3, -5)
168
[6.61]
+V
+V
-V
-V
FG( )
AC(L)
AC(N)
M4
Cover
(option)
(14.5)
Terminal cover TB1
[0.57]
(24)
[0.94]
2-M3
Mounting hole
78±0.5
[3.07]
Name plate
¶ Tolerance : ±1 [±0.04]
¶ Weight : 560g max (without cover)
¶ PCB Material/thickness : CEM3 / 1.6mm [0.06]
¶ Chassis material : Aluminum
¶ Dimensions in mm, [ ]= inches
¶ Mounting torque : 0.49N • m(5kgf • cm)max
¶ Mounting torque : M4:1.6N • m(16.9kgf • cm)max
¶ Keep drawing current per pin below 20A for TB1.
¶ Please connect safety ground to FG terminal on the unit.
139.5 ±0.5
[5.49]
A
Point A
58.5
[2.3]
PBA150F
2-M3
Mounting
hole
Connector type
CN3 Option (Mfr : J.S.T.)
Pin No. Contents
1
RC(+)
2
RC( - )
Barrier strip type
Model B2B-XH-A
9
Mating Connector (Terminal)
[0.35]
XHP-2
( ) BXH-001T-P0.6
or SXH-001T-P0.6
PBA/PBW-15