English
Language : 

41696005X-3 Datasheet, PDF (14/56 Pages) List of Unclassifed Manufacturers – PC, DVI, VIDEO, HD Component INTERFACE CONTROLLER FOR TFT PANEL
Summary: Jumpers setting
Ref
Purpose
Note
JA1
JA2
JA3
JA5
JA6
JB1
JB2
JB3
JB5
JC1– JC16
JP2
JP4
JP6
JT1
JT2
JT3
JT4
JT5
JT6
JT7
JT8
S1 & S2
SW3
SW4
On board +5V logic power enable
On board +3.3V logic power enable
Panel power voltage select
CAUTION: Incorrect setting can damage
panel
Panel power voltage select
CAUTION: Incorrect setting will cause panel
damage
Panel power voltage select
CAUTION: Incorrect setting will cause panel
damage
Backlight brightness voltage range
Backlight inverter on/off control – signal level
Backlight inverter on/off control – polarity
Backlight control type selection
Custom configuration
Reserved
Custom configuration
Input power control
Composite video-in terminator enable
S-Video luma-in terminator enable
S-Video chroma-in terminator enable
Component luma-in terminator enable
Component Cr-in terminator enable
Component Cb-in terminator enable
Composite video 2-in terminator enable
Reserved
LVDS or TTL panel selection
Panel & function selection
Panel & function selection
1-2 & 3-4 closed, factory set, do not remove
1-2 & 3-4 closed, factory set, do not remove
See panel voltage setting table 1
See panel voltage setting table 1
See panel voltage setting table 1
1-2 closed = 3.3V max
2-3 closed = 5V max
2-3 = On/Off control signal ‘High’ = +5V
1-2 = On/Off control signal ‘High’ = +3.3V
Open = On/Off control signal ‘High’ = Open collector
CAUTION: Incorrect setting can damage inverter.
1-2 = control signal ‘high’ = CCFT ON
2-3 = control signal ‘low’ = CCFT ON
1-2 = VR/Digital switch mount control
3-4 = Analog backlight brightness - voltage range 0~5V
5-6 = PWM (Pulse Width Modulation) brightness
JC2 : Display “Save to Calibrated Defaults” under Reset
to Factory Defaults menu.
JC3 : Closed = Enable baud rate selection function in
programming mode
Reserved
1-2 = Reserved
3-4 = On-board programming
5-6 = Display “Blue only” function on OSD menu
Short = External switch control
Open = Switch mount control
Open = composite video input is not terminated
Close = composite video input is terminated with 75Ω
Open = S-video luma input is not terminated
Close = S-video luma input is terminated with 75Ω
Open = S-video chroma input is not terminated
Close = S-video chroma input is terminated with 75Ω
Open = component luma input is not terminated
Close = component luma input is terminated with 75Ω
Open = component Cr input is not terminated
Close = component Cr input is terminated with 75Ω
Open = component Cb input is not terminated
Close = component Cb input is terminated with 75Ω
Open = composite video input is not terminated
Close = composite video input is terminated with 75Ω
Reserved
LVDS panel : All OFF
TTL panel : All ON
See table 2
See table 3
14