B0207C-F Datasheet, PDF (13/16 Pages) List of Unclassifed Manufacturers – MBA 0204; MBB 0207; MBE 0414 Professional leaded resistors
BCcomponents
Professional leaded resistors
Product specification
MBA 0204; MBB 0207;
MBE 0414
TESTS AND REQUIREMENTS
Essentially all tests are carried out in accordance with the
following specifications:
EN 140000 / IEC 60115-1, Generic specification
(includes tests)
EN 140100 / IEC 60115-2, Sectional specification
(includes schedule for qualification approval)
CECC 40 101-806, Detail specification (includes schedule
for conformance inspection)
Most of the components are approved in accordance with
the European CECC-system, where applicable. Table 5
contains only the most important tests. For the full test
schedule refer to the documents listed above. The testing
also covers most of the requirements specified by EIA/IS-703
and JIS-C-5202.
The tests are carried out in accordance with IEC 60068 and
under standard atmospheric conditions in accordance with
IEC 60068-1, 5.3. Climatic category LCT/UCT/56 (rated
temperature range: Lower Category Temperature, Upper
Category Temperature; damp heat, long term, 56 days) is
valid.
Unless otherwise specified the following values apply:
Temperature: 15 °C to 35 °C
Relative humidity: 45% to 75%
Air pressure: 86 kPa to 106 kPa (860 mbar to
1 060 mbar).
For testing the components are mounted on a test board in
accordance with IEC 60115-1, 4.31 unless otherwise
specified.
In Table 5 only the tests and requirements are listed with
reference to the relevant clauses of IEC 60115-1 and
IEC 60068-2; a short description of the test procedure is also
given.
Table 5 Test procedures and requirements
IEC
60 115-1
CLAUSE
IEC
60 068-2
TEST
METHOD
TEST
PROCEDURE
REQUIREMENTS
PERMISSIBLE CHANGE (∆R/R)
4.5
4.8.4.2
4.25.1
stability for product
types:
STABILITY
CLASS 0,5
STABILITY
CLASS 1
STABILITY
CLASS 2
MBA 0204 1 Ω to 332 kΩ
0,22 Ω to < 1 Ω
> 332 kΩ
MBB 0207 1 Ω to 1 MΩ
0,22 Ω to < 1 Ω
> 1 MΩ
MBE 0414 1 Ω to 2,4 MΩ
0,22 Ω to < 1 Ω
> 2,4 MΩ
−
resistance
±5%; ±1%; ±0,5%
−
temperature at 20 / LCT / 20 °C
coefficient and
20 / UCT / 20 °C
±50 ppm/K; ±25 ppm/K
−
endurance at U = P70 × R or
70 °C:
U = Umax;
standard
1,5 h on; 0,5 h off
operation
mode
70 °C; 1000 h
±(0,5% + 0,05 Ω) ±(0,5% + 0,05 Ω)
±0,5%
70 °C; 8000 h
±(1% + 0,05 Ω)
±(1% + 0,05 Ω)
±1%
−
endurance at U = P70 × R or
70 °C:
U = Umax;
long term 1,5 h on; 0,5 h off
operation
mode
70 °C; 1000 h ±(0,25% + 0,05 Ω) ±(0,25% + 0,05 Ω)
±0,25%
70 °C; 8000 h
±(0,5% + 0,05 Ω) ±(0,5% + 0,05 Ω)
±0,5%
2002 Oct 07