N79E715 Datasheet
Figure 16-8 Flow and Status of Master Receiver Mode
16.4.3 Slave Receiver Mode
In Slave Receiver mode, several bytes of data are received form a master transmitter. Before a
transmission is commenced, I2ADDR should be loaded with the address to which the device will
respond when addressed by a master. I2CLK does not affect in slave mode. The AA bit should be set
to enable acknowledging its own slave address or General Call. After the initialization above, the I2C
wait until it is addressed by its own address with the data direction bit “write” (SLA+W) or by General
Call addressing. The slave receiver mode may also be entered if arbitration is lost.
After the slave is addressed by SLA+W, it should clear its SI flag to receive the data from the master
transmitter. If the AA bit is 0 during a transaction, the slave will return a non-acknowledge after the
next received data byte. The slave will also become not addressed and isolate with the master. It
cannot receive any byte of data with I2DAT remaining the previous byte of data which is just received.
(STA,STO,SI,AA) = (0,0,0,1)
If own SLA+W is received,
ACK will be transmitted
60H
Own SLA+W has been received
ACK has been transmitted
I2DAT = own SLA+W
OR
68H
Arbitration lost and own SLA+W
has been received
ACK has been transmitted
I2DAT = own SLA+W
(STA,STO,SI,AA)=(X,0,0,1)
Data byte will be received
ACK will be transmitted
(STA,STO,SI,AA)=(X,0,0,0)
Data byte will be received
NACK will be transmitted
80H
Data byte has been received
ACK has been transmitted
I2DAT = Data Byte
88H
Data byte has been received
NACK has been transmitted
I2DAT = Data Byte
A0H
A STOP or repeated
START has been received
(STA,STO,SI,AA)=(0,0,0,0)
Not addressed slave
will be entered; no recognition
of own SLA or General Call
(STA,STO,SI,AA)=(0,0,0,1)
Not addressed slave will be
entered; own SLA will be
recognized; General Call will
be recognized if GC = 1
(STA,STO,SI,AA)=(1,0,0,0)
Not addressed slave will be
entered; no recognition of own
SLA or General Call;
A START will be transmitted
when the bus becomes free
(STA,STO,SI,AA)=(1,0,0,1)
Not addressed slave will be
entered; own SLA will be
recognized; General Call will
be recognized if GC = 1;
A START will be transmitted
when the bus becomes free
Jan. 6, 2016
Page 106 of 189
Revision 1.01