English
Language : 

PS222S Datasheet, PDF (10/13 Pages) List of Unclassifed Manufacturers – 3-Channel Secondary Monitoring IC With Over-Current Protection And an Additional 12V OCP Channel
PS222S
Notes:
1. Zener diode or resistor or both of them can be used in component X.
2. The bypass capacitor Cby suggests to be 0.1uF~ 10uF and layout nearby pin VCC.
3. The recommend sense values of RS12(1), RS12(2), RS5 and RS33 are ≥ 0.002Ω.
4. Over-Current Protection design example:
(1)
I ref
= 20µA , RI
= VRI
I RI
= 1.25 = 62.5K (Ω)
20µ
(2) RS5=0.002 Ω , ∆V5V = 0.002 × I+5V = ROC5 × 8 × Iref
(3)
If +5V OCP trip point is 20A,
ROC 5
=
0.002 × 20
8 × 20µ
=
250(Ω)
5. GND path:
(1) The GND path width is wider as far as it could.
(2) The better grounding ability has better performance at surge test.
6. PS222S uses single 12VOCP protection function:
As “Typical 3 rails SPS” application circuit, the pin7(ISx) must be connected a
resistor(Resistance>10kΩ) to GND or floating.
3-Channel Secondary Monitoring IC
Version:A.001
-9-