English
Language : 

WM3-96 Datasheet, PDF (1/13 Pages) List of Unclassifed Manufacturers – Energy Management Modular Smart Power Quality Analyzer
Energy Management
Modular Smart Power Quality Analyzer
Type WM3-96
• Class 0.5 (current/voltage)
• 32-bit µP-based modular smart power quality analyzer
• Graph display (128x64 dots)
• Front size: 96x96 mm
• Measurements of single phase and system variables: W, Wdmd,
var, VA, VAdmd, PF, PFavg, V, A, An dmd (for all of them max. and
min. values). Energies: kWh and kvarh on 4 quadrants.
• Neutral current measurement
• TRMS measurement of distorted waves (voltage/current)
• Current and voltage inputs with autoranging capability
• 4x4-dgt instantaneous variable read-out
• 4x9-dgt total energies read-out
• 4x6-dgt partial energies read-out
• 48 independent energy meters to be used as single,
dual, multi-time energy management
• Display refresh time: 100 msec @ 50 Hz
• Harmonic distorsion analysis (FFT) up to 50th harmonic
with both graph and numerical indication (of current
and voltage)
• Harmonics source detection
• Optional RS232 + real time clock function with data
logging of alarm and MIN/MAX events, monthly energy
metering recording
• Degree of protection (front): IP 65
• Up to 4 optional alarm setpoints
• Up to 4 optional pulse outputs
• Up to 4 optional analogue outputs
• Optional serial RS 422/485 output
• Universal power supply: 18 to 60VAC/DC - 90 to 260 VAC/DC
• MODBUS RTU, JBUS, (N2 METASYS protocols on request)
Product Description
Ordering Key WM3-96AV53H XX XX XX XX X
32-bit µP-based smart power
quality analizer with a built-in
configuration key-pad.
The housing is for panel
mounting and ensures a
degree of protection (front) of
IP 65. The instrument is par-
ticularly indicated for those
application where there is the
need to control the power
supply quality. The variables
being displayed are more
than 400.
Model
Range code
System
Power supply
Slot A
Slot B
Slot C
Slot D
Options
Type Selection
Range code
Slot A (signal retransmission) Slot B (signal retransmission) Slot C (alarm or pulse out)
AV5:
AV7:
240/415 VAC -
1/5 AAC
(max. 300 V (L-N)/
520 V (L-L) - 6 A)
(standard)
400/690VAC -
1/5 AAC
(max. 480V (L-N) /
830 V (L-L) / 6 A 1)
System
3: One phase, three-
phase system
(3 or 4 wires, balan-
ced load)
Three phase system
(3 or 4 wires, unba-
lanced load)
Power supply
L: 18 to 60VAC/DC 1)
H: 90 to 260VAC/DC
1) On request
XX: None
XX: None
A1: Single analogue output, B1: Dual analogue output,
20mADC (standard)
20mADC (standard)
A2: Single analogue output, B2: Dual analogue output,
±5mADC 1)
±5mADC 1)
A3: Single analogue output, B3: Dual analogue output,
±10mADC 1)
±10mADC 1)
A4: Single analogue output, B4: Dual analogue output,
±20mADC 1)
±20mADC 1)
B1: Dual analogue output, W1: Dual analogue output,
20mADC (standard)
10VDC (standard)
B2: Dual analogue output, W2: Dual analogue output,
±5mADC 1)
±1VDC 1)
B3: Dual analogue output, W3: Dual analogue output,
±10mADC 1)
±5VDC 1)
B4: Dual analogue output, W4: Dual analogue output,
±20mADC 1)
±10VDC 1)
V1: Single analogue output, S1: Serial port,
10VDC (standard)
RS485 multidrop,
V2: Single analogue output,
bidirectional 1)
±1VDC 1)
V3: Single analogue output, Note:
±5VDC 1)
V4: Single analogue output, Slot A + Slot B
±10VDC 1)
Max 4 analogue outputs
W1: Dual analogue output,
10VDC (standard)
Slot C + Slot D
W2: Dual analogue output, max 4 digital outputs
±1VDC 1)
W3: Dual analogue output,
±5VDC 1)
W4: Dual analogue output,
±10VDC 1)
Specifications are subject to change without notice WM3-96DS260606
XX: None
R1: Single relay output,
(AC1-8AAC, 250VAC) 1)
R2: Dual relay output,
(AC1-8AAC, 250VAC) 1)
O1: Single open collector
output (30V/100mADC) 1)
O2: Dual open collector out-
put (30V/100mADC) 1)
D1: 3 digital inputs 1)
Slot D (alarm or pulse out)
XX: None
R2: Dual relay output,
(AC1-8AAC, 250VAC) 1)
O2: Dual open collector out-
put (30V/100mADC) 1)
O4: 4 open collector out-
puts (30V/100mADC) 1)
Options
X: None
S: Serial RS232 + RTC
N: With N2 Metasys protocol
C : options: S+N
1