FEATURES
• VERY HIGH ACCURACY: 3.000 V OUTPUT ±200 µV
• EXTREMELY LOW DRIFT: 0.6 ppm/°C 55°C to +125°C
• LOW WARM-UP DRIFT: 1 ppm Typ.
• EXCELLENT STABILITY: 6 ppm/1000 Hrs. Typ.
• EXCELLENT LINE REGULATION: 3 ppm/V Typ.
• HERMETIC 14-PIN CERAMIC DIP
• MILITARY PROCESSING OPTION
APPLICATIONS
• PRECISION A/D and D/A CONVERTERS
• TRANSDUCER EXCITATION
• ACCURATE COMPARATOR THRESHOLD
REFERENCE
• HIGH RESOLUTION SERVO SYSTEMS
• DIGITAL VOLTMETERS
• HIGH PRECISION TEST and
MEASUREMENT INSTRUMENTS
DESCRIPTION
VRE117 Series Precision Voltage References
provide ultrastable +3.000V (VRE117), -3.000V
SELECTION GUIDE
(VRE118) and ±3.000V (VRE119) outputs with
±0.200 mV initial accuracy and temperature
coefficient as low as 0.6 ppm/°C over the full
military temperature range. This improvement in
accuracy is made possible by a unique,
proprietary multipoint laser compensation
technique developed by Thaler Corporation.
Type
VRE117C
VRE117CA
VRE117M
VRE117MA
Output
Temperature
Operating Range
+3.0V
+3.0V
+3.0V
+3.0V
-25°C to +85°C
-25°C to +85°C
-55°C to +125°C
-55°C to +125°C
Max. Volt
Deviation
200 µV
100 µV
400 µV
200 µV
Significant improvements have been made in
VRE118C -3.0V -25°C to +85°C 200 µV
other performance parameters as well, including
VRE118CA -3.0V -25°C to +85°C 100 µV
initial accuracy, warm-up drift, line regulation, and
VRE118M -3.0V -55°C to +125°C 400 µV
long-term stability, making the VRE117 series the
VRE118MA -3.0V -55°C to +125°C 200 µV
most accurate and stable 3.0V reference
available.
VRE119C ±3.0V -25°C to +85°C
VRE119CA ±3.0V -25°C to +85°C
200 µV
100 µV
VRE117/118/119 devices are available in two
VRE119M ±3.0V -55°C to +125°C 400 µV
operating temperature ranges, -25°C to +85°C
VRE119MA ±3.0V -55°C to +125°C 200 µV
and -55°C to +125°C, and two performance
grades. All devices are packaged in 14-pin hermetic ceramic packages for maximum long-term stability. "M"
versions are screened for high reliability and quality.
Superior stability, accuracy, and quality make these references ideal for precision applications such as A/D
and D/A converters, high-accuracy test and measurement instrumentation, and transducer excitation.
VRE117DS REV. C NOV 2000