English
Language : 

VAF505 Datasheet, PDF (1/4 Pages) List of Unclassifed Manufacturers – AC-DC Power Supplies PCB Mount type
AC-DC Power Supplies PCB Mount type
VAF5
Ordering information
VAF 5 05
1
2
3
R
1Series name
2Output wattage
3Output voltage
VAF
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
VAF503
3.3
VOLTAGE[V] 3.3
CURRENT[A] 1.0 (Peak 1.2)
VAF505
5.0
5
1.0 (Peak 1.2)
VAF512
5.4
12
0.45 (Peak 0.54)
VAF515
5.25
15
0.35 (Peak 0.42)
VAF524
5.28
24
0.22 (Peak 0.27)
SPECIFICATIONS
MODEL
VAF503
VAF505
VAF512
VAF515
VAF524
VOLTAGE[V]
CURRENT[A]
AC85 - 264 1f or DC110 - 370
ACIN 100V 0.15typ (Io=100%)
ACIN 200V 0.10typ (Io=100%)
INPUT
FREQUENCY[Hz]
47 - 440 or DC
ACIN 100V 15typ (Io=100%)
INRUSH CURRENT[A] ACIN 200V 30typ (Io=100%)
LEAKAGE CURRENT[mA] 0.5max (60Hz, According to IEC60950 and DEN-AN)
EFFICIENCY[%]
68typ
77typ
78typ
78typ
81typ
VOLTAGE[V]
3.3
5
12
15
24
CURRENT[A]
*1 1.0 (Peak 1.2)
1.0 (Peak 1.2)
0.45 (Peak 0.54)
0.35 (Peak 0.42)
0.22 (Peak 0.27)
LINE REGULATION[mV] 20max
20max
48max
60max
96max
LOAD REGULATION[mV] 40max
40max
100max
120max
150max
0 to +55C*2 80max
80max
120max
120max
150max
RIPPLE[mVp-p]
-10 - 0C*2 140max
140max
160max
160max
200max
Io=100 - 120%*2 180max
180max
200max
200max
240max
OUTPUT
0 to +55C*2 120max
RIPPLE NOISE[mVp-p] -10 - 0C*2 160max
120max
160max
150max
180max
150max
180max
200max
230max
Io=100 - 120%*2 200max
200max
220max
220max
260max
TEMPERATURE COEFFICIENT[mV] -10 to +55C 100max
50max
120max
150max
300max
DRIFT[mV]
*3 20max
20max
48max
60max
96max
OUTPUT VOLTAGE SETTING[V] 3.19 - 3.47
4.90 - 5.30
11.40 - 12.60
14.25 - 15.75
23.0 - 25.0
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] Fixed
START-UP TIME[ms]
700max (ACIN 85V, Io=100%)
HOLD-UP TIME[ms]
10typ (ACIN 85V, Io=100%), 20typ (ACIN 100V, Io=100%)
PROTECTION OVERCURRENT PROTECTION Works over 125% of rating and recovers automatically
CIRCUIT OVERVOLTAGE PROTECTION Works over 115% of rating (By zener diode clamping)
INPUT-OUTPUT
ISOLATION INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
VIBRATION
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature)
-10 to +71C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
19.6m/s2 10 - 55Hz, 3minutes period, 60minutes each along X, Y and Z axis (Non operating)
IMPACT
196.1m/s2 11ms, once each X, Y and Z axis (Non operating)
SAFETY AND AGENCY APPROVALS
NOISE
REGULATIONS CONDUCTED NOISE
UL60950-1, C-UL, EN60950-1, EN50178 Complies with DEN-AN and IEC60950-1
Complies with FCC-B, VCCI-B, CISPR22-B, EN55022-B
OTHERS
CASE SIZE/WEIGHT
COOLING METHOD
32X20X72.5mm [1.26X0.79X2.85 inches] (WXHXD) / 30g max
Convection
*1 Peak load for 10sec. or less in acceptable if the total wattage is less than the rated wattage.
*2 This is the value that measured on measuring board with capasitor of 22mF. Measuared by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM101).
*3 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
VAF-2