English
Language : 

TRC-200 Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – Switch Mode LED Drivers
200W TRC-200 Series
Switch Mode LED Drivers
Constant Current
Aluminum Housing
Electrical Specifications
Input Voltage Range:
100 - 277 Nom. Vac (90 - 305 V Min/Max)
Frequency:
50/60 Hz Nom. (47-63 Hz Min/Max)
Power Factor:
>0.90 @ full load, 100V through 277V
Inrush Current:
65 Amps maximum @ 230 Vac, cold start 25ºC
Input Current:
2.4 A max 100Vac, 1.2 A max 220Vac
Maximum Power:
200W
Line Regulation:
± 1%
Load Regulation:
± 3%
Leakage Current:
1 mA 277 Vac 60Hz
Typical Efficiency
89-91% at 277Vac
Turn-on Delay:
0.5S typical 110Vac, 0.3S typical 220Vac
Ripple and Noise:
Protection:
3% Vo
Over-Voltage, Over-Temperature (110°C), Lightning,
and Short Circuit Protection with Self Recovery
Environmental Specifications
Minimum Starting Temp: -35ºC
Storage Temperature:
-40ºC to +85ºC
Humidity:
5% to 100%
Cooling:
Convection
Sound Rating:
Class A
MTBF:
330,000 Hours (450 mA model) @ 110Vac input, 80%
load and 25ºC ambient conditions per MIL-HDBK-217F
Lifetime:
Weight:
60,000 Hours @ 220Vac, 80% load and 45ºC ambient
3.31 lbs. (1.5 kg)
Safety and EMC Compliance
UL/CUL
UL8750, Compliance to UL1012,
CAN/CSA-C22.2 No. 0, CSA-C22.2 No. 107.1-01, CSA-C22.2 No. 250.0
CE
EN 61347-1, EN61347-2-13
EN 55015
Conducted emission Test & Radiated emission Test
EN 61000-3-2 Harmonic current emissions
EN 61000-3-3 Voltage fluctuations & flicker
EN 61000-4-2 Electrostatic Discharge (ESD): 8 kV air discharge, 4 kV contact discharge
EN 61000-4-3 Radio-Frequency Electromagnetic Field Susceptibility Test-RS
EN 61000-4-4 Electrical Fast Transient / Burst-EFT
EN 61000-4-5 Surge Immunity Test: AC Power Line: line to line 4 kV, line to earth 6 kV
EN 61000-4-6 Conducted Radio Frequency Disturbances Test-CS
EN 61000-4-8 Power Frequency Magnetic Field Test
EN 61000-4-11 Voltage Dips
EN 61547
Electromagnetic Immunity Requirements Applies to Lighting Equipment
• Total Power: 120 Watts
• Input Voltage: 100-277 Vac Nom.
• UL Dry & Damp Location Rated
• IP67
• High Efficiency
• High Power Factor with Active Correction
• Output and Lightning Protection
Standard Versions - Product Specifications
Model Number
Output Current Output Voltage Max. Output Typical
(mA)*
Range (Vdc) Power (W) Efficiency
TRC-200S045ST
450
267-445
200
93%
TRC-200S070ST
700
171-285
200
93%
TRC-200S105ST
1050
114-190
200
92%
TRC-200S140ST
1400
85-142
200
92%
TRC-200S175ST
1750
68-114
200
92%
TRC-200S210ST
2100
57-95
200
91%
TRC-200S245ST
2450
48-81
200
91%
TRC-200S280ST
2800
42-71
200
91%
TRC-200S315ST
3150
38-63
200
91%
TRC-200S350ST
3500
34-57
200
90%
TRC-200S420ST
4200
28-47
200
90%
TRC-200S490ST
4900
24-40
200
90%
TRC-200S560ST
5600
21-35
200
89%
TRC-200S630ST
6300
19-32
200
89%
TRC-200S833ST
8330
14-24 Vc
200
88%
* The output current is adjustable at factory from 50% to 100%.
E332160
Note:
LED drivers are designed and intended to operate LED loads only.
Non-LED loading may be outside the specified design limits of our
LED drivers, and therefore cannot be covered by any warranty.
If you desire to use our LED drivers to operate non-LED loads
please contact us to discuss compatibility.
Specifications subject to change without notice.
Rev 9-1-15
Thomas Research Products • 1225 Bowes Rd • Elgin, IL 60123 • T 847-515-3057 • F 847-515-3047 • www.trpssl.com