SU3000RTXL3UHV Datasheet, PDF (1/7 Pages) List of Unclassifed Manufacturers – SmartOnline 3kVA On-Line Double-Conversion UPS, 3U Rack/Tower, 208/240V NEMA outlets
SmartOnline 3kVA On-Line Double-Conversion
UPS, 3U Rack/Tower, 208/240V NEMA outlets
MODEL NUMBER: SU3000RTXL3UHV
Highlights
3000VA / 3kVA / 2400 watt
on-line double-conversion 3U
rack/tower UPS
208/240V +/-2% output at
50/60Hz
Expandable runtime,
Hot-swappable battery modules
RS232 port; support for
SNMP/WEB card options
Front panel status LEDs with
detailed load and battery metering
NEMA L6-20P input; 6-15/20R &
L6-20R outlets
Package Includes
SU3000RTXL3UHV Rack-Tower
UPS System
Description
3000VA / 3kVA on-line, double-conversion UPS system for critical server, network and telecommunications
equipment. 3U rackmount form factor with an installed depth of 20 inches (50.8cm). Expandable battery runtime
with optional external battery packs BP72V15-2U (limit 1), BP72V28RT-3U (multi-pack compatible) and
BP72V18-2US (multi-pack compatible). Full time sine wave 200/208/220/240V AC output with +/-2% voltage
regulation. Online, double-conversion Uninterruptible Power Supply (UPS) actively converts raw incoming AC
PowerAlert Software and cabling
Mounting hardware for 4 post
rackmount enclosures/tower
stands included
Warranty information
Instruction manual
power to DC, then re-converts output back to completely regulated, filtered AC output. Operates continuously
without using battery power during brownouts to 130V and overvoltages to 275V. NEMA L6-20P input plug. NEMA 6-15/20R & L6-20R output receptacles.
Network-grade AC surge and noise suppression. Zero transfer time between AC and battery operation. Network management interfaces support simultaneous
communications via DB9 serial port and SNMPWEBCARD slot. Built-in DB9 port offers both enhanced RS-232 enabled monitoring data, plus contact closure
monitoring ability. Supports simultaneous detailed monitoring of equipment load levels, self-test data and mains power conditions via all network interfaces.
Includes PowerAlert monitoring software and complete cabling. Integrated two bank PDU switching supports load shedding and remote-reboot of connected
equipment. Multi-stage metered current monitoring and battery charge status LEDs. Mains power and voltage regulation LEDs. Audible Alarm. Self-test.
Fault-tolerant auto-bypass mode. 4 post rackmount accessories included; 2-9USTAND tower kit and 2POSTRMKITWM 2-post rackmount accessories
available. Field replaceable, hot swappable internal batteries and external battery packs. Attractive all-black UPS design. $250,000 Ultimate Lifetime
Insurance.
Features
True on-line, double conversion UPS provides pure, sine wave AC output at all times
Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time
Removes harmonic distortion, electrical impulses, frequency variations and other hard to solve power problems
Accepts input voltages between 160 and 275 (130 to 275 at loads under 70%), regulating output to selectable 200/208/220/240V +/-2%
3000VA/2400 watt power capacity with 8 total outlets (6 NEMA6-15/20R & 2 NEMAL6-20R)
Standard internal battery set provides 14 minutes runtime at half load
Expandable runtime with external battery packs BP72V15-2U (limit 1), BP72V28RT-3U (multi-pack compatible) and BP72V18-2US (multi-pack
compatible)
Innovative design makes unit adaptable for rackmount, tower, or stacking applications