English
Language : 

SS-5H Datasheet, PDF (1/3 Pages) List of Unclassifed Manufacturers – 300V Subminiature, Radial Leaded, Time-Delay Fuses
300V Subminiature, Radial Leaded, Time-Delay Fuses
SS-5H Series
HALOGEN
HF
FREE
Pb
Radial Leaded Device
Rated
Current
1A-6.3A
Electrical Characteristics
1.5 xIn 2.1 xIn 2.75 xIn
4 xIn
10 xIn
min max min max min max min max
1 hr 2 min 400 mS 10 Sec. 150 mS 3 Sec. 20 mS 150 mS
Description
Radial leaded, time delay subminiature fuse with high breaking capacity,
designed to IEC 60127-3, Sheet 4. SS-5H series provides protection up to
300Vac with an interrupting rating of 100A.
Features
• Plastic cap and base, flammability UL 94V0 for additional protection
• Protects against harmful overcurrents in primary and secondary
applications
• Small rectangular-leaded design minimizes PCB space
• Solderability to save cost for additional mounting components
• High frequency vibration: MIL-STD-202F, Method 201A
• Halogen-free
• RoHS compliant
• Lead-free
Applications
• Power supplies
• Notebooks
• White goods
• Lighting ballasts
• Power adapters
• Printers
• Set top boxes
• Battery chargers
• TVs / Displays
• Air conditioners
Agency Information
• cURus approval: Guide JDYX2, File E 19180 and Guide JDYX8,
File E19180
• VDE approval: Certificate No: 40031800
• TUV approval: Certificate No: J 50190080
• CQC approval: Certificate No: CQC11012056980
• PSE approval: Certificate No: JET 1641-31007-1006 (1-5A);
JET 1641-31007-1007 (6.3A)
• KC-Mark approval: Certificate No: SU05011-11001 (1~2.5A);
SU05011-11002 (3.15~6.3A)
Part Number System
SS-5H -1A –APH
Series Number
Amp Rating
Packaging Code Suffix and Voltage Rating
Ordering
• Specify product and packaging code (i.e., SS-5H-1A-AP)
• Packaging Codes: Ammo Pack (1000 fuses); -AP=250V, -APH=300V
Bulk Polybag (200 fuses); -BK=250V, -BKH=300V
Specifications
Catalog
Number
SS-5H-1A
SS-5H-1.25A
SS-5H-1.6A
SS-5H-2A
SS-5H-2.5A
SS-5H-3.15A
SS-5H-4A
SS-5H-5A
SS-5H-6.3A
Voltage
Rating
(Vac)1
300
300
300
300
300
300
300
300
300
Interrupting Rating
(amps) @ Rated
Voltage (50Hz)
100
100
100
100
100
100
100
100
100
Typical DC Cold
Resistance (mW)†
78
57
43
31.15
23
17.5
12
7.35
7.40
Typical
Melt I2t*
7.4
12.75
23
29.8
40.3
67
87
120
176
Typical Voltage
Agency Information
Drop@1In (mV)‡ VDE1 TUV1 cURus1 CQC1 KC-Mark1 PSE1
94.5
X2
X
X
X
X
X
93.5
X2
X
X
X
X
X
71.5
X
X
X
X
X
X
75
X2
X
X
X
X
X
74.5
X2
X
X
X
X
X
62.5
X
X
X
X
X
X
65.4
X
X
X
X
X
X
43
X
X
X
X
X
X
59
X
X
X
X
X
X
* I2t Value is measured at 10In DC.
† Typical Cold Resistance (Measured at <10% of rated current).
‡ Typical Voltage Drop (Voltage drop was measured at 20°C ambient temperature at rated current).
1. CQC and KC-Mark Voltage rating only 250Vac. VDE, TUV, cURus and PSE voltage ratings given at
both 250Vac and 300Vac.
2. Pending VDE voltage ratings: 250Vac (1.25, 2.5A), 300Vac (1, 1.25, 2, 2.5A)
0914 BU-SB11759
Page 1 of 3
Data Sheet 4416