English
Language : 

SFX-0500 Datasheet, PDF (1/10 Pages) List of Unclassifed Manufacturers – specification describes the requirements of 200,220,250,275Watts
En_h_a_n_c_e_E_l_e_c_tr_o_n_ic_s__C_o_.,_L_T_D______________________________________________________________P_r_o_d_u_c_t_S_p_e_c_if_ic_a_t_ion
MODEL NO. SFX-0500(80PLUS) SERIES (ACTIVE PFC)
This specification describes the requirements of 200,220,250,275Watts with full range voltage
with a Micro-ATX(SFX-1.0&1.1) form-factor and SFX 12V,fan control,+5V standby voltage
remote on/off ,and forced air cooling characteristics.
F1. AC INPUT
1.1 AC input requirements
The input voltage, current, and frequency requirements for continuous
operation are stated below.
Table 1 AC Input Line Requirements
Parameter
Min
Nom.
Max
Vin
90
100 -
240
264
Vin Frequency
47
63
Iin(200,220W)
3
1.3
Iin(250W)
Iin(275W)
3.5
1.5
4
2
Unit
VACrms
Hz
A
A
Power factor correction (PF)>0.90 at full load.
1.2 Inrush current regulation
The power supply must meet inrush requirements for any rated AC voltage, during turn on at any phase
of AC voltage, during a single cycle AC dropout condition, during repetitive ON/OFF cycling of AC,
and over the specified temperature range (Top). The peak inrush current shall be less than the ratings
of its critical components (including input fuse, bulk rectifiers, and surge limiting device).
F2. DC OUTPUT
2.1 DC voltage regulation
Parameter
Range
+3.3V
±5%
+5V
±5%
+12V1
±5%
+12V2
±5%
-12V
±10%
+5VSb
±5%
Min
+3.14
+4.75
+11.4
+11.4
-10.8
+4.75
Nom.
+3.3
+5.0
+12.0
+12.0
-12.0
+5.0
1.At no load,3.3V output +/-5% regulation limits do not apply.
Max
+3.47
+5.25
+12.6
+12.6
-13.2
+5.25
Unit
Volts
Volts
Volts
Volts
Volts
Volts
AUDIT:________李復新_________CHECK:__________________DESIGN:_________李麗萍__________
SFX-0500 S (80PLUS ) SPEC REV: 40
1 OF 10