English
Language : 

S506-32MA Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – 5mm x 20mm Fuses
5mm x 20mm Fuses
S506 Series, Time Delay, Glass Tube
Description
• Time delay, low breaking capacity
• Optional axial leads available
• 5mm x 20mm physical size
• Glass tube, nickel-plated brass endcap construction
• Designed to IEC 60127-2 (32mA-10A)
S506 ELECTRICAL CHARACTERISTICS
2.1 In 2.75 In
4 In
10 In
In
max min max min max min max
32mA-100mA 2 min 200 ms 10 sec 40 ms 3 sec 10 ms 300 ms
125mA-6.3A 2 min 600 ms 10 sec 150 ms 3 sec 20 ms 300 ms
8A-12.5A 2 min 600 ms 10 sec 150 ms 3 sec 20 ms 300 ms
Agency Information
• UL Recognized Card: (32mA-10A) Guide JDYX2,
File E19180
• CSA Component Acceptance: File 53787
• cURus Recognition: Guide JDYX8, File E19180
• Semko Approval, 32mA-10A
• VDE Approval, 32mA-10A
• BSI Approval, 32mA-10A
• IMQ Approval, 32mA-10A
• MITI Approval, 32mA-10A
Ordering
• Specify packaging, product, and option code
• For -R option, drop mA or A from product code
(i.e. S506-2-R)
RoHS
2002/95/EC
Dimensions
Drawing Not to Scale
• Ratings above 6.3A have a 0.8mm diameter lead
• With TR2 packaging code, lead wire length is 19.05mm
Product Code
S506-32mA
S506-40mA
S506-50mA
S506-63mA
S506-80mA
S506-100mA
S506-125mA
S506-160mA
S506-200mA
S506-250mA
S506-315mA
S506-400mA
S506-500mA
S506-630mA
S506-800mA
S506-1A
S506-1.25A
S506-1.6A
S506-2A
S506-2.5A
S506-3.15A
S506-4A
S506-5A
S506-6.3A
S506-8A
S506-10A
S506-12.5A
Voltage
Rating
AC
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
SPECIFICATIONS
Interrupting Rating
Typical DC
at Rated Voltage (50Hz) Cold Resistance
AC
(ohms)*
35A
21.7
35A
14.2
35A
9.5
35A
7.1
35A
4.5
35A
2.8
35A
2.0
35A
1.3
35A
1.0
35A
0.66
35A
0.46
35A
0.37
35A
0.268
35A
0.191
35A
0.131
35A
0.064
35A
0.046
35A
0.039
35A
0.029
35A
0.024
35A
0.018
40A
0.013
50A
0.010
63A
0.009
80A
0.007
100A
0.005
125A
0.004
* DC Cold Resistance (Measured at <10% of rated current)
† Minimum Pre-Arching I2t (Measured at 10 In and rated voltage)
‡ Maximum Voltage Drop (Voltage drop was measured at 20°C ambient temperature at rated current)
Minimum
Pre-Arching I2t
(A2Sec) AC†
0.0014
0.0034
0.006
0.012
0.015
0.022
0.034
0.052
0.078
0.17
0.41
0.61
0.67
1.0
2.2
2.7
6.7
9.7
15
25
51
88
150
214
192
420
812
Maximum
Voltage
Drop (mV)‡
1050
920
800
760
580
490
390
320
340
270
250
210
190
170
150
90
85
85
85
85
80
80
75
75
80
75