English
Language : 

RUMC3AB1BD Datasheet, PDF (1/5 Pages) List of Unclassifed Manufacturers – universal plug-in relay - Zelio RUM - 3 C/O - 24 V DC - 10 A
Product data sheet
Characteristics
Complementary
Shape of pin
[Ui] rated insulation voltage
[Uimp] rated impulse withstand voltage
Contacts material
[Ie] rated operational current
Minimum switching current
Maximum switching voltage
Minimum switching voltage
Resistive rated load
Maximum switching capacity
Minimum switching capacity
Operating rate
Mechanical durability
Electrical durability
Average consumption in W
Average consumption in VA
Drop-out voltage threshold
Operating time
Average resistance
Rated operational voltage limits
7/9/2011
RUMC3AB1BD
universal plug-in relay - Zelio RUM - 3 C/O - 24
V DC - 10 A
Main
Range of product
Series name
Product or component
type
Device short name
Contacts type and
composition
Contacts operation
Control circuit voltage
[Ithe] conventional
enclosed thermal
current
Status LED
Control type
Coil interference
suppression
Utilisation coefficient
Sale per indivisible
quantity
Zelio Relay
Universal
Plug-in relay
RUM
3 C/O
Standard
24 V DC
10 A at <= 55 °C
Without
Pushbutton
Without
20 %
10
Cylindrical
250 V conforming to IEC
300 V conforming to CSA
300 V conforming to UL
4 kV conforming to IEC 61000-4-5
Silver alloy (Ag/Ni)
10 A (AC-1/DC-1) NO conforming to IEC
12 A at 28 V (DC-1) conforming to UL
16 A at 277 V (AC-1) conforming to UL
5 A (AC-1/DC-1) NC conforming to IEC
10 mA
250 V AC conforming to IEC
250 V DC conforming to IEC
17 V
10 A at 250 V AC
10 A at 28 V DC
2500 VA, AC circuit
280 W, DC circuit
170 mW
<= 200 cyc/mn (no-load)
<= 30 cyc/mn (under load)
5000000 cycles
100000 cycles for resistive load
1.4 W, DC circuit
2...3, AC circuit
>= 0.1 Uc (DC
>= 0.15 Uc (AC
20 ms between coil de-energisation and making of the Off-delay contact (AC/DC)
20 ms between coil energisation and making of the On-delay contact (AC/DC)
470 Ohm, DC circuit at 20 °C +/- 10 %
19.2...26.4 V DC
1