English
Language : 

RSS50-150 Datasheet, PDF (1/1 Pages) List of Unclassifed Manufacturers – HPS Rapid Restrike
RSS-50-150
Rapid Smart Start Series
HPS Rapid Restrike
Features
• Minimizes delays or hesitation during hot lamp restarting
• Prevents “End of Life” lamps from continuous cycling over
long periods of time
• Operates with most 52-55 volt HPS lamps between 50-150 watts
• Remains unaffected by stray voltages, moderate overvoltages,
as well as undervoltage conditions
• Drops into the background during normal lamp operation
with less than 1.3% insertion loss
• Hot restart time is typically less than .5 second, but may vary
due to lamp construction, ballast design and ballast supply voltage
• Starter operation will not exceed one minute under “failed lamp” condition
• Starter reset time is typically less than 800 milliseconds after
ballast supply voltage has been removed
• Operation is independent of ballast “X3” lead,
allowing for remote ballast applications
• Starter must be located within 12” of lamp socket
• Power consumption during normal lamp operation less than .3%
• Case temperature rating of 105°C
The Rapid Smart Start lamp reignitor is an electronic device
designed to cold start and rapidly restart hot HPS lamps after
momentary power interruptions or drops in supply voltage.
Wiring
Black
HV Lead
Rapid Smart
Starter
Common
White
Lamp
Dimensions
Body: 12” leads, stripped 0.25”
3.5"
2.0"
MADE IN USA
Of Imported And Domestic Components
Specifications subject to change without notice.
Rev 5-20-15
Thomas Research Products • 1215 Bowes Rd • Elgin, IL 60123 • T 847-515-3057 • F 847-515-3047 • www.trpssl.com