English
Language : 

ROB-6V330ME3 Datasheet, PDF (1/4 Pages) List of Unclassifed Manufacturers – ROB Miniature Aluminum Electrolytic Capacitors For Audio
ROB Miniature Aluminum Electrolytic Capacitors For Audio
s TONEREX
• Adopting the newly developed formation method and composite electrolytic paper for audio application has reduced distortion,
achieving high-quality sound.
• Gold-printing on a black sleeve. (labeled “TONEREX”)
• All lead wires are oxygen-free copper wires to reduce distortion.
Outline Drawing
Vent (except φ5)
Sleeve
φd ± 0.05 copper wire
(tinned)
Photo
L + α max.
15 min. 5 min.
Lead spacing and wire diameter
φD
5
6.3
8
F
2.0
2.5
3.5
φd
0.6
α
1.5
10
12.5
16
18
5.0
7.5
0.8
1.5 for L16 max.
2.0 for L20 min.
Unit: mm
Specifications
No.
Item
Performance
1
Temperature range (°C)
–40 to +85
2
Leakage current (µA)
Less than 0.01 CV or 4 whichever is larger (after five minutes) C: Capacitance (µF), V: Voltage (V)
3
Capacitance tolerance (%)
±20
(20°C, 120 Hz)
Tangent of loss angle
4
(tan δ)
Endurance
5
(85°C)
(Applied ripple current)
Rated voltage (V) 6.3
10
16
25 35
50 63 100
tan δ
0.24 0.20 0.16 0.14 0.12 0.10 0.09 0.08
0.02 is added to each 1000 µF increase over 1000 µF
(20°C,
120 Hz)
Test time
Leakage current
Change in capacitance
tan δ
1000 hrs
Initial specified value or less
Within ±20% of initial value
150% or less of initial specified value
6
Max. storage temp. (85°C)
7
Applicable Standards
Test time 500 hrs. Others have same as endurance in No. 5. Voltage application treatment.
JIS C 5101-1, 5101-4 1998 (IEC 60384-1 1992, 60384-4 1985)
Coefficients of Frequency for Ripple Current
Frequency (Hz)
50 • 60 120
Rated Voltage (V) Rated Voltage (V)
6.3 to 16
25 to 35
50 to 100
All CV value
≤1000
1000 <
≤1000
1000 <
0.8
1
0.8
1
0.8
1
0.8
1
0.8
1
1k
10 k
100 k
1.1
1.2
1.2
Coefficients of Temperature for Ripple Current
1.5
1.7
1.7
1.2
1.3
1.3
Temperature (°C)
+70 or less
+85
1.6
1.9
1.9
1.2
1.3
1.3
Coefficients
1.35
1
12321
This catalog printed in U.S.A. on 1/2001.
Specification and dimensions in this catalog are subject to change without notice.
If necessary, drawings can be provided.