Coax Cable
Construction
Item
Inner conductor
Dielectric
Outer conductor
Material
Silver plated copper
PTFE
Copper tube / tin-plated copper tube
Diameter (Inch / mm)
0.0641 ±0.001 1.63 ±0.03
0.209 ±0.002
5.3 ±0.05
0.250 ±0.001 6.35 ±0.03
Electrical Characteristics
Capacitance (pF/m)
Impedance (Ω)
Velocity of propagation (%)
Inner conductor DCR (Ohm / km)
Maximum operating frequency (GHz)
Maximum operating voltage (RMS)
Minimum inside bend radius (mm)
Minimum corona extinction voltage (Vrms)
Minimum voltage withstand (Vrms)
Operating temperature range (°C)
: 95.1
: 50 ±0.5
: 69.5
: 8.4
: 18
: 3,000
: 22.2
: 3,000
: 7,500
: -55 to +125
Attenuation and Average Power
Frequency
(GHz)
Attenuation
(dB/ft)
(dB/meter)
0.5
0.05
0.16
1
0.07
0.23
5
0.17
0.56
10
0.27
0.89
18
0.48
1.57
Average Power
(Watts CW)
1,332.1
914.6
364.4
238.2
200
Part Number Table
Description
Cable, Coax, Semi Rigid, RG401, 1M
Part Number
RG401
Important Notice : This data sheet and its contents (the "Information") belong to the members of the Premier Farnell group of companies (the "Group") or are licensed to it. No licence is granted for the use of
it other than for information purposes in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change without notice and replaces
all data sheets previously supplied. The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness, any error in or omission from it or for any use
made of it. Users of this data sheet should check for themselves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted.
Liability for loss or damage resulting from any reliance on the Information or use of it (including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising)
is excluded. This will not operate to limit or restrict the Group's liability for death or personal injury resulting from its negligence. pro-POWER is the registered trademark of the Group. © Premier Farnell plc 2011.
www.element14.com
www.farnell.com
www.newark.com
www.cpc.co.uk
21/11/11 V1.1