Language : 

PFE500-28 Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – 300 to 714W AC-DC Power Module
PFE300-700
300 to 714W AC-DC Power Module
‹ Low profile, small size
‹ 100°C baseplate temperature
‹ High power density
‹ High Efficiency
‹ Suitable for conduction cooling
Features and Benefits
Feature
‹ Low profile
‹ High Efficiency
‹ Power Factor Corrected (PFC)
‹ Operation up to 100°C baseplate
Benefit
‹ Assists system integration
‹ Easier to cool
‹ Supports Global Use
‹ Operates in harsh environments
Specifications
MODEL
ITEMS
AC Input
Input Current (100 / 220VAC) A
Model dependant
Inrush Current (100 /200VAC) (1) A
Power Factor
Output Voltage Setpoint Accuracy -
Ripple and Noise
(1) -
Over Current Protection
%
Over Voltage Protection
-
Series Operation
-
Parallel Operation
-
Power On Signal (ENA)
-
Auxilliary Supply
-
Remote On/Off (Opto isolated) -
Overtemperature Protection
Operating Baseplate Temp.
°C
Storage Temperature
°C
Humidity (non condensing)
Cooling
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Safety Certifications
Weight
g
Size (WxHxL)
mm
in
Warranty
yrs
PFE300
PFE700
PFE500F
PFE500
(Preliminary)
VAC 85 to 265VAC, 47-63Hz (Operation to 440Hz possible(3))
4.0 / 2.0
8.8 / 4.4
6.8 / 3.4
6.2 / 3.2
20 / 40 peak
0.95 minimum
±2%
±1V
±2%
1%
4V
1%
105 - 140% (Automatic Recovery)
125 - 145%
60 - 69.6V
125 - 145%
Yes
No
Yes (Droop mode)
Yes (Single wire)
Open collector (10mA sink current). Low (on) when output is present
None
None
10 - 14V, 20mA
None
None
High = On
Yes
-40 to +100°C (2)
-40 to +100°C
Operating: 20 - 95%RH, Non Operating: 10 - 95%RH
Conduction
Input to Output 3kVAC, Input to Baseplate 2.5kVAC, Output to Baseplate 1.5kVDC
Output to baseplate: 100M Ohm at 500VDC, 25°C ambient, 70%RH
10-55Hz (1 min sweep), constant amplitude 0.825mm (max 49m/s2), X, Y, Z 1 hour each
196.1m/s2
UL60950-1, CSA60950-1 (cUL), EN60950-1, CE mark (LVD)
250
250
300
61 x 12.7 x 116.8mm
70 x 12.7 x 122mm
2.4 x 0.5 x 4.6”
2.76 x 0.5 x 4.8”
2 years
Notes: (Consult Installation Manual for detailed specifications, test methods and
application notes)
1) External components are required, consult Application Notes
2) PFE500-12 & PFE500F-12: -40 to 85°C. See instruction manuals for derating curves
3) Requires the use of an undervoltage relay or similar. Contact technical support
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4