PDUMH15NET Datasheet, PDF (1/4 Pages) List of Unclassifed Manufacturers – Single-Phase Switched PDU, 1.4kW 15A 120V, 1U Horizontal Rackmount, 16 NEMA 5-15R outlets, NEMA 5-15P input plug
Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
Model Number: PDUMH15NET
Single-Phase Switched PDU, 1.4kW 15A 120V, 1U Horizontal Rackmount, 16 NEMA 5-15R outlets, NEMA 5-15P
input plug
Highlights
Switched 15A 120V PDU, 1U horizontal rackmount format
Reports voltage, frequency & load level via ethernet interface
Visual current meter, Reversible housing
NEMA 5-15P input with attached 12 ft. / 3.6m line cord
16 NEMA 5-15R switched outlets with cord retention brackets
Temperature, humidity and contact closure monitoring options
Description
Tripp Lite single phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off,
recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption.
PowerAlert interface supports remote control and custom notification of user-specified conditions via email, secure web, SNMP, Telnet or SSH
interface. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed
for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads
as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware.
PDU output current consumption in amps is continuously displayed locally via visual meter and remotely via web/network interface to warn of
potential overloads before critical IT mains or branch breakers trip.
Applications
Ideal means of powering networking equipment in datacenters, computer rooms and network closets
Package Includes
PDU with attached 5-15P input power cord
Installable 1U mounting brackets
PowerAlert software
User manual
Features
15A 120V Switched Power Distribution Unit / PDU with built-in web/network interface (Agency derated to 12A continuous)
Attached NEMA 5-15P 120V single phase input; 12 ft. / 3.6m cord
1U horizontal rackmount form factor
16 switched NEMA 5-15R outlet (8 front / 8 rear)
Supports power-on, power-off or reboot of each outlet on a real-time or programmable basis
Enables reboot of locked equipment, custom power-on/power-off sequences, load-shedding of optional loads and disabling unused outlets
Network interface provides PDU control and data regarding input voltage and total output load level in amps
Digital display continuously reports total output load level in amps
Supports user-specified alarm notification thresholds
In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4
optional SRSWITCH door sensors
DHCP/Manual configuration support
10/100 Mbps auto-sensing