English
Language : 

MRG5902 Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – Coaxial cables used in cabled distribution networks designed according the European
TECHNICAL DATA SHEET
COAX RG59 LSNH
code MRG5902
version 2
date 2005-12-12
page 1/2
APPLICATION
Coaxial cables used in cabled distribution networks designed according the European
Standard EN 50117 operating at frequencies between 5 MHz and 860 MHz and the
International Standard IEC 1196.
CONSTRUCTION
12 3 4
1 Inner conductor Copper clad steel
2 Dielectric
Solid PE
3 Braid
Annealed copper
4 Sheath
LSNH according the European Standard HD 624.
REQUIREMENTS AND TEST METHODS
Test methods in accordance with European standard EN 50117-1.
Mechanical characteristics
1. Inner conductor.
Diameter:
2. Dielectric:
Diameter:
3. Outer conductor:
Diameter screen:
Coverage braid:
4. Sheath:
Diameter:
Tensile strength:
Elongation at break:
5. Cable:
Crush resistance of cable:
Storage/operating temperature:
Minimum installation temperature:
Minimum static bend radius:
Total weight:
0.58 mm ± 0.02 mm
3.7 mm ± 0.15 mm
4.3 mm ± 0.2 mm
91 % ± 4 %
6.15 mm ± 0.2 mm
≥ 12.5 N/mm2
≥ 150 %
< 1% (load of 700N)
-15°C to +70°C
-5 °C
35 mm
100 g/m
© Belden Wire & Cable B.V.