MIL-STD-461 Datasheet, PDF (1/10 Pages) List of Unclassifed Manufacturers – 2A EMI Filter Module | |||
|
MIL-STD-461 EMI INPUT FILTER
FGDS-2A-50V up to 2A CURRENT HHi-iR-eRlel
GGrardaede
2A EMI Filter Module
9 to 50 VDC Input Range
MIL-STD-461C/D/E Compliant
⢠To comply with MIL-STD-461D/E power leads :
⢠CE 102 : Emission requirement over 10KHz to 10MHz
⢠CS 101 : Susceptibility requirement over 30Hz to 150KHz
⢠CS 114 : Susceptibility requirement over 10KHz to 400MHz
⢠CS 115 : Susceptibility requirement for spikes
1-General
⢠To comply with MIL-STD-461C power leads :
⢠CE 03 : Emission requirement over 15KHz to 50MHz
⢠CS 01 : Susceptibility requirement over 30Hz to 50KHz
⢠CS 02 : Susceptibility requirement over 15KHz to 400MHz
⢠CS 06 : Susceptibility requirement for spikes
⢠To comply with DO-160C/D/E power lines :
⢠Conducted emission requirement over 15KHz to 30MHz
⢠Conducted susceptibility requirement over 10KHz to 400MHz
⢠Susceptibility requirement for induced transients
The GAIA Converter filter module FGDS-2A-50V
provides a state-of-the-art product to fulfill
Electromagnetic Interferences (EMI) requirements
for Aerospace/Defence applications.
The FGDS-2A-50V complies with major standards
including :
⢠the US MIL-STD-461 rev C, rev D and rev E
⢠the international DO-160 rev C, rev D and rev E
In particular, the filter module is compliant with
the following requirements of MIL-STD-461C/D/E
standards :
⢠Temperature range :
⢠operating temperature : -40°C/+105°C case
⢠storage temperature : -55°C/+125°C
⢠MIL-STD-461C Part 2. & 3. requirements :
⢠Conducted Emission (CE)
⢠CE03, power leads, emission over
15KHz to 50MHz, narrowband, Class A1
⢠CE03, power leads, emission over
15KHz, broadband, Class A1 curve#
1&2
⢠Conducted Susceptibility (CS)
⢠CS01, power leads, frequency over 30Hz
to 50KHz, class A1, consult factory
for criteria
⢠CS02, power leads, frequency 15KHz
to 400MHz, class A1
⢠CS06, power leads, spike #1
⢠MIL-STD-461D/E Part 2. & 3. requirements :
⢠Conducted Emission (CE)
⢠CE102, power leads, emission over
10KHz to 10MHz, basic curve
⢠Conducted Susceptibility (CS)
⢠CS101, power leads, frequency 30Hz
to 150KHz, curve #1
⢠CS114, bulk cable injection, frequency
10KHz to 400MHz,
⢠CS115, spikes, bulk cable injection,
calibrated spike
⢠DO-160-C/D/E requirements :
⢠Conducted Emission (CE)
⢠Section 21 power lines, emission over
15KHz to 30MHz, category B, AZ & LMH
⢠Conducted Susceptibility (CS)
⢠Section 20 power lines, frequency 10KHz
to 400MHz
6
In addition, this filter withstands in a transparent
state without dammage the transient and spike
requirements of :
⢠MIL-STD-704A with 80V/100ms & 600V/10µs
⢠MIL-STD-1275B with 100V/50ms & 250V/70µs
The FGDS-2A-50V is suitable for all GAIA
Converter DC/DC converters and architecture
⢠from 4W up to 50W power
⢠up to 2A input current
⢠up to 50V permanent input voltage.
2-Product Selection
FGDS-2A-50V (/T) and/or (/S)
(/T) : option for -55°C start up operating temperature.
(/S) : option for screening and serialization
REDEFINING THE SOURCE OF POWER
© Gaia Converter FC05-050.03/08 Revision B
For locations, phone, fax, E-Mail see back cover
|
▷ |