KD-J2A-002 Datasheet, PDF (1/13 Pages) List of Unclassifed Manufacturers – RELAY - NONLATCH 3 PST/NO +AUX, 25 AMP
ENGINEERING DATA SHEET
APPLICATION NOTES:
101
002
103E
007
APPLICABLE SOCKET:
SO-1059-8914
SERIES KD
RELAY - NONLATCH
3 PST/NO +AUX, 25 AMP
All welded construction
Contact arrangement
Qualified to
3 PST configuration with 1 PDT, 2 Amp
auxiliary contacts in one inch cube
MIL-PRF-6106
PRINCIPLE TECHNICAL CHARACTERISTICS
Contacts rated at
28 Vdc and 115/200 Vac, 400 Hz, 3Ø
Weight
0.188lb max
Dimensions
1.01in x 1.01in x 1.00in
Hermetically sealed, corrosion resistant metal can.
Detail specifications and ordering data appear on the following
pages.
CONTACT ELECTRICAL CHARACTERISTICS
Contact rating
per pole and load
type [1]
@28 Vdc @115 Vac
400 Hz
Resistive [2]
Inductive [3]
Motor
Lamp
Overload
Rupture
25
25
12
15
10
10
5
5
50
80
60
100
Contact rating of auxiliary contacts
at 28 Vdc or 115 Vac, 400 Hz
Load current in Amps
@115/200 Vac, 400 Hz, 3Ø @115/200 Vac, 60 Hz, 3Ø
[10]
25
2.5
15
2.5
10
2
5
1
80
N/A
100
N/A
Resistive
2 Amp
Inductive
1 Amp
Lamp
0.5 Amp
Featuring LEACH© power and control solutions
www.esterline.com
AMERICAS
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622
.
.
Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
EUROPE
2 Rue Goethe
57430 Sarralbe
France
.
.
Tel: (33) 3 87 97 31 01
Fax: (33) 3 87 97 96 86
ASIA
Units 602-603 6/F Lakeside 1
No.8 Science Park West Avenue
Phase Two, Hong Kong Science Park
Pak Shek Kok, Tai Po, N.T.
Hong Kong
Tel: (852) 2 191 3830
Fax: (852) 2 389 5803
Data sheets are for initial product selection and comparison. Contact Esterline Power Systems prior to choosing a component.
Date of issue: 07/10
- 163 -
Page 1 of 4