English
Language : 

HLG-80H-24A Datasheet, PDF (1/7 Pages) List of Unclassifed Manufacturers – 80W Single Output Switching Power Supply
80W Single Output Switching Power Supply
HLG-80H series
■ Features :
•Universal AC input / Full range (up to 305VAC)
•Built-in active PFC function
•Protections: Short circuit / Over current / Over voltage / Over temperature
•Cooling by free air convection
•OCP point adjustable through output cable or internal potentiometer
•IP67 / IP65 design for indoor or outdoor installations
•"UL8750 listed" safety approved for HLG-80H- BL
•Class 2 power unit
•Three in one dimming function (1~10Vdc or PWM signal or resistance)
•Suitable for LED lighting and moving sign applications
•Compliance to worldwide safety regulations for lighting
•Suitable for dry / damp / wet locations
•5 years warranty (Note.10)
F 110
HLG-80H-12 A
M M SELV IP65 IP67
(for HLG-80H-48/54 only) (except for HLG-80H-48/54)
(except for BL type) (except for HLG-80H-48/54BL)
(for HLG-80H-48/54BL only)
(for HLG-80H-12~42BL only)
Blank : IP67 rated. Cable for I/O connection.
A : IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance.
BL (option) : Contact MEAN WELL for details.
D (option) : IP67 rated. Timer dimming function, contact MEAN WELL for details.
SPECIFICATION
MODEL
HLG-80H-12 HLG-80H-15 HLG-80H-20 HLG-80H-24 HLG-80H-30 HLG-80H-36 HLG-80H-42 HLG-80H-48 HLG-80H-54
OUTPUT
DC VOLTAGE
12V
15V
20V
24V
30V
36V
42V
48V
54V
CONSTANT CURRENT REGION Note.4 7.2 ~12V 9 ~ 15V
12 ~ 20V 14.4 ~ 24V 18 ~ 30V 21.6 ~ 36V 25.2 ~ 42V 28.8 ~ 48V 32.4 ~ 54V
RATED CURRENT
5A
5A
4A
3.4A
2.7A
2.3A
1.95A
1.7A
1.5A
RATED POWER
60W
75W
80W
81.6W
81W
82.8W
81.9W
81.6W
81W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p 200mVp-p 200mVp-p 200mVp-p
VOLTAGE ADJ. RANGE Note.6 10.8 ~ 13.5V 13.5 ~ 17V 17 ~ 22V 22 ~ 27V 27 ~ 33V 33 ~ 40V 38 ~ 46V 43 ~ 53V 49 ~ 58V
CURRENT ADJ. RANGE
Can be adjusted by internal potentiometer A type only
3 ~ 5A
3 ~ 5A
2.4 ~ 4A 2.04 ~ 3.4A 1.62 ~ 2.7A 1.38 ~ 2.3A 1.17 ~ 1.95A 1.02 ~ 1.7A 0.9 ~ 1.5A
VOLTAGE TOLERANCE Note.3 ±2.5%
±2.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
LINE REGULATION
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
LOAD REGULATION
±2.0%
±1.5%
±1.0%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
SETUP, RISE TIME Note.8 1200ms,80ms/115VAC 500ms,80ms/230VAC at full load ; B type 1200ms,200ms/115VAC 500ms,200ms/230VAC at 95% load
HOLD UP TIME (Typ.)
16ms at full load 230VAC /115VAC
INPUT
VOLTAGE RANGE Note.5 90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.96/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
TOTAL HARMONIC DISTORTION THD< 20% when output loading≧60% at 115VAC/230VAC input and output loading≧75% at 277VAC input
EFFICIENCY (Typ.)
88%
89%
90%
90.5%
91%
91%
91%
91%
91%
AC CURRENT (Typ.)
0.85A / 115VAC 0.425A / 230VAC 0.4A / 277VAC
INRUSH CURRENT (Typ.)
COLD START 70A(twidth=485μs measured at 50% Ipeak) at 230VAC
LEAKAGE CURRENT
<0.75mA / 277VAC
OVER CURRENT
95 ~ 108%
Note.4
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT
PROTECTION
OVER VOLTAGE
Hiccup mode, recovers automatically after fault condition is removed
14 ~ 17V 18 ~ 24V 23 ~ 30V 28 ~ 35V 35 ~ 43V
Protection type : Shut down o/p voltage, re-power on to recover
41 ~ 49V
48 ~ 58V
54 ~ 63V
59 ~ 68V
OVER TEMPERATURE
Shut down o/p voltage, re-power on to recover
WORKING TEMP.
-40 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 95% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 60℃)
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750, CSA C22.2 No. 250.0-08(except for HLG-80H-48/54V & HLG-80H-48/54BL), UL8750 listed for HLG-80H-□BL
SAFETY STANDARDS Note.7
EN61347-1, EN61347-2-13 independent, J61347-1, J61347-2-13, IP65 or IP67 approved ; Design refer to UL60950-1, TUV EN60950-1
SAFETY & WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
EMC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
Compliance to EN55015, EN61000-3-2 Class C (≧60% load) ; EN61000-3-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
MTBF
357.8K hrs min. MIL-HDBK-217F (25℃)
OTHERS DIMENSION
195.6*61.5*38.8mm (L*W*H)
NOTE
PACKING
0.84Kg; 16pcs/14.4Kg/0.54CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to "DRIVING METHODS OF LED MODULE".
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. A type only.
7. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
10. Refer to warranty statement.
11.To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.
File Name:HLG-80H-SPEC 2013-12-25