HIGHLINER2 Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – LED lighting for Indoor & Outdoor | |||
|
HighLINER 2
LED lighting for Indoor & Outdoor
HighLINER 2 is designed to replace fluorescent lighting in applications such as coolers,
stock rooms, wall washes, soffits, and canopies. HighLINER 2 is easy to install and is a simple
solution to save energy and reduce ongoing maintenance costs.
⢠Improves walkway and aisle visibility and building aesthetics
⢠Fits easily into new or existing interior and exterior surfaces
⢠Saves up to 64% energy compared with typical fluorescent fixtures
Co-extruded housing â Eliminates sealing surfaces by using two materials which are
formed togetherâan opaque white for the back and a diffused lens material in the front.
Wire channel â Powers lights by running a header wire above the housing to connect
multiple HighLINER 2s while hiding the power source.
Wire cover â Snaps onto the ends of HighLINER 2 to cover wire connections and/or
bridge distances between lights.
Specifications
Electrical
Input voltage
100-240 VAC, 50-60 Hz
Output voltage
24 VDC, Class 2 low voltage
Input power
System1 Luminaire2
4â²
17 W
14.4 W
1â²
4W
3.6 W
System efficacy
105 lm/W
Lighting
Light output3
Light distribution
Color temperature (K)
Color rendering (CRI)
4â²
1â²
Linear
5000 K
80
1792 lumens
448 lumens
Performance
Ingress Protection
UL location rating
Operating temperature
Life rating
Dimming
IP66
Dry, damp, and wet locations
-25 °C to 50 °C
100,000 hours (L70)4
Optional Motion Sensing
(see Cold Series Dimming Control data sheet)
Construction
Housing
Body color
Acrylic, impact modified with UV stabilization
White
Mounting
4â²
1â²
Mounting clips (3 included)
Wire nut housing (2 included)
Mounting clips (2 included)
Wire nut housing (2 included)
Documentation
Warranty
Agency listings
Files available
5-year limited
UL (NSF/ANSI 2), ETL, CE,
DesignLights Consortium® (DLC), RoHS
LM-79, LM-80, IES
1 For calculating the maximum number of luminaires that can be connected to a power supply, use the LUMINAIRE INPUT POWER.
2 For calculating the maximum number of luminaires that can be connected to the branch circuit, use the SYSTEM INPUT POWER.
3 Tolerance range for optical and electrical data: ±15%.
4 Based on LED component manufacturer data.
Multi-Application
Downlighting
Project Name/Location
Part Number
Notes#
Date
1
NSF/ANSI 2