HE3B
Key features include:
• 3 position funtionality (OFF – ON – OFF) as required for manual robotic control
• Provides a high level of safety based on human behavioral studies that deter-
mine personnel may squeeze OR let go when presented with a panic situation
• Contacts will not re-close when released from Off➔On (3➔1)
(per IEC60204-1; 9.2.5.8)
• Multiple contacts for enhanced reliability
• Snap acting contacts from position 1 to 2
• Available with or without rubber cover
Conforming to Standards
Approvals
Operating Temperature
Operating Humidity
Storage Temperature
Pollution Degree
Contact Resistance
Insulation Resistance
Impulse Withstand Voltage
Operating Frequency
Mechanical Life
Electrical Life
Shock Resis-
tance
Operating Extremes
Damage Limits
Vibration Resis- Operating Extremes
tance
Damage Limits
Terminal
Recommended Wire Size
Solder Heat Resistance
Terminal Pulling Strength
Recommended Screw Torque
Degree of Protection
Conditional Short-Circuit Current
Recommended Short Circuit Protection
Weight
Circuit Opening Force
IEC60947-5-1, EN60947-5-1, JIS C8201-5-1, UL508, CSA C22.2
No 14
ISO12100/EN292, IEC60204-1/EN60204-1, ISO11161/prEN11161,
ISO10218/EN775, ANSI/RIA R15.06
–25 to +60˚C (no freezing)
45 to 85% RH maximum (no condensation)
–40 to +80˚C (no freezing)
3
50mΩ maximum (beginning stage)
Between live & dead metal parts:
100MΩ maximum (at 500VDC mega)
Between positive & negative live parts:
100MΩ minimum (at 500VDC mega)
1.5kV
1200 operations/hour
Position 1➔2 1 million minimum
Position 1➔2➔3➔1: 100 thousand minimum
100,000 minimum at rated load
100m/s2
1000m/s2
5 to 55Hz, applitude 0.5mm minimum
16.7Hz, applitude 1.5mm minimum
0.110” quick connect / solder terminal
0.5mm2 maximum / 1 line
260°C / 3 seconds maximum
20N minimum
0.68 to 0.88N • m
with rubber cover: IP65,
without rubber cover: IP40 (IEC 60529),
50A (125V)
125V/10A fast blow fuse (IEC 60127-1)
without rubber cover - Approx. 14g
with rubber cover - Approx. 18g
500N minimum