English
Language : 

GVAD0110 Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – auxiliary contact
Product data sheet
Characteristics
Complementary
Mounting location
[Ui] rated insulation voltage
[Ue] rated operational voltage
[Ith] conventional free air thermal current
Protection type
Mechanical durability
Minimum switching current
Minimum switching voltage
Rated operational power in VA
Rated operational power in W
Oct 15, 2014
GVAD0110
TeSys GV2 & GV3 - auxiliary contact - 1 NO +
1 NC (fault)
Main
Range
Device short name
Product or component
type
Product compatibility
Auxiliary contacts oper-
ation
Pole contact composi-
tion
Connections - terminals
TeSys
GVAD
Auxiliary contact block
GV2L
GV2LE
GV2ME
GV2P
GV2RT
GV3L
GV3P
Fault signal 1 NC
1 NO + 1 NC
Screw clamp terminals 1 cable 0.75...1.5 mm² - ca-
ble stiffness: flexible - with cable end
Screw clamp terminals 2 cable 0.75...1.5 mm² - ca-
ble stiffness: flexible - with cable end
Screw clamp terminals 2 cable 0.75...2.5 mm² - ca-
ble stiffness: flexible - without cable end
Screw clamp terminals 1 cable 0.75...2.5 mm² - ca-
ble stiffness: flexible - without cable end
Screw clamp terminals 2 cable 1...2.5 mm² - cable
stiffness: solid
Screw clamp terminals 1 cable 1...2.5 mm² - cable
stiffness: solid
Left side
300 V - conforming to CSA C22.2 No 14
300 V - conforming to UL 508
690 V - conforming to IEC 60947-1
24...240 V DC
48...690 V AC
2.5 A for fault signalling
6A
GG fuse <= 10 A
GB2CB... circuit breaker rating according to operational current for Ue <= 415 V
100000 cycles
5 mA
17 V
72 VA at 110...127 V AC-14 - electrical durability: 1000 cycles
48 VA at 48 V AC-14 - electrical durability: 1000 cycles
36 VA at 24 V AC-14 - electrical durability: 1000 cycles
850 VA at 380...415 V AC-15 - electrical durability: 100000 cycles
720 VA at 230...240 V AC-15 - electrical durability: 100000 cycles
650 VA at 440 V AC-15 - electrical durability: 100000 cycles
500 VA at 500 V AC-15 - electrical durability: 100000 cycles
500 VA at 110...127 V AC-15 - electrical durability: 100000 cycles
400 VA at 690 V AC-15 - electrical durability: 100000 cycles
300 VA at 48 V AC-15 - electrical durability: 100000 cycles
9 W at 60 V DC-13 - electrical durability: 1000 cycles
24 W at 24 V DC-13 - electrical durability: 1000 cycles
15 W at 48 V DC-13 - electrical durability: 1000 cycles
240 W at 48 V DC-13 - electrical durability: 100000 cycles
180 W at 60 V DC-13 - electrical durability: 100000 cycles
140 W at 24 V DC-13 - electrical durability: 100000 cycles
140 W at 110 V DC-13 - electrical durability: 100000 cycles
120 W at 240 V DC-13 - electrical durability: 100000 cycles
1