English
Language : 

GF3500LV Datasheet, PDF (1/1 Pages) List of Unclassifed Manufacturers – Thermally Conductive, Low Outgassing, Liquid Gap Filling Material
Gap Filler 3500LV (Two-Part)
Thermally Conductive, Low Outgassing, Liquid Gap Filling Material
Features and Benefits
• Thermal Conductivity: 3.5 W/m-K
• Low volatility for outgassing sensitive
applications
• Ultra-conforming with excellent wet-out
for low stress interfaces on applications
• 100% solids - no cure by-products
Gap Filler 3500LV is a two-part, high thermal
conductivity, liquid gap filling material. This
material offers the mechanical property
benefits of a silicone material with the
additional feature of low outgassing.
The mixed material will cure at room
temperature or can be accelerated with
the addition of heat.
The liquid approach offers infinite thickness
variations with little to no stress to sensitive
components during assembly. As cured,
Gap Filler 3500LV provides a soft,
form-in-place elastomer that is ideal for fragile
assemblies or for filling intricate air voids.
Typical Applications:
• Lighting
• Automotive in-cabin electronics
• Medical electronics
• Industrial controls
• Optics
TYPICAL PROPERTIES OF GAP FILLER 3500LV
PROPERTY
IMPERIAL VALUE METRIC VALUE TEST METHOD
Color / Part A
Blue
Blue
Visual
Color / Part B
White
White
Visual
Viscosity, High Shear (Pa-s) (1)
45
45
ASTM D5099
Density (g/cc)
3.1
3.1
ASTM D792
Mix Ratio
1:1
1:1
—
Shelf Life @ 25°C (months)
5
5
—
PROPERTY AS CURED
Color
Light Blue
Light Blue
Visual
Hardness (Shore 00) (2)
40
40
ASTM D2240
Heat Capacity (J/g-K)
0.8
0.8
ASTM D1269
Siloxane Content, ∑D4-D10 (ppm)
40
40
—
Continuous Use Temp (°F) / (°C)
-76 to 392
-60 to 200
—
ELECTRICAL AS CURED
Dielectric Strength (V/mil)
275
275
ASTM D149
Dielectric Constant (1000 Hz)
8.0
8.0
ASTM D150
Volume Resistivity (Ohm-meter)
1010
1010
ASTM D257
Flame Rating
V-O
V-O
U.L. 94
THERMAL AS CURED
Thermal Conductivity (W/m-K)
3.5
3.5
ASTM D5470
CURE SCHEDULE
Working Time @ 25°C (3)
240 min (4 hrs) 240 min (4 hrs)
—
Cure @ 25°C (hrs) (3)
24
24
—
Cure @ 100°C (min) (3)
30
30
—
1) Capillary Viscosity, 1500/sec, Part A and B measured separately.
2) Thirty second delay value Shore 00 hardness scale.
3) Parallel plate rheometer, see reactivity application note.
Building a Part Number
Standard Options
GF3500LV – 00 – 240 – 50cc –
NA
NA = Selected standard option. If not selecting a standard
option, insert company name, drawing number, and
revision level.
Cartridges: 50cc = 50.0cc, 400cc = 400.0cc
Kits: 1200cc = 1200.0cc, or 10G = 10 gallon
Working Time: 240 = 240 minutes
00 = No spacer beads
07 = 0.007" spacer beads
10 = 0.010" spacer beads
GF3500LV = Gap Filler 3500LV Material
Note: To build a part number, visit our website at www.bergquistcompany.com.
Configurations Available:
• Supplied in cartridge or kit form
The Bergquist Company -
North American Headquarters
18930 West 78th Street
Chanhassen, MN 55317
Phone: 800-347-4572
Fax: 952-835-0430
www.bergquistcompany.com
The Bergquist Company -
European Headquarters
Netherlands
Phone: 31-35-5380684
Fax: 31-35-5380295
The Bergquist Company -
Asia Headquarters
Hong Kong
Phone: 852-2690-9296
Fax: 852-2690-3408
All statements, technical information and recommendations herein are based on tests we believe to be reliable, and
THE FOLLOWING IS MADE IN LIEU OF ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THE IMPLIED
WARRANTIES OF MARKETABILITY AND FITNESS FOR PURPOSE. Sellers’ and manufacturers’ only obligation shall be to
replace such quantity of the product proved to be defective. Before using, user shall determine the suitability of the product
for its intended use, and the user assumes all risks and liability whatsoever in connection therewith. NEITHER SELLER NOR
MANUFACTURER SHALL BE LIABLE EITHER IN TORT OR IN CONTRACT FOR ANY LOSS OR DAMAGE, DIRECT,
INCIDENTAL, OR CONSEQUENTIAL, INCLUDING LOSS OF PROFITS OR REVENUE ARISING OUT OF THE USE OR
THE INABILITY TO USE A PRODUCT. No statement, purchase order or recommendations by seller or purchaser not
contained herein shall have any force or effect unless in an agreement signed by the officers of the seller and manufacturer.
PDS_GF3500LV_0515