English
Language : 

FP1007R6 Datasheet, PDF (1/4 Pages) List of Unclassifed Manufacturers – High Current, High Frequency, Power Inductors
High Current, High Frequency, Power Inductors
Flat-Pac™ FP1007R6 Series
HALOGEN
HF
FREE
Pb
Description
• Halogen free, lead free, RoHS compliant
• 125°C Maximum total temperature operation
• 10.5 x 8.0 x 7.0mm Maximum surface mount package
• Ferrite core material
• Controlled DCR tolerance for sensing circuits
• Inductance Range from 150nH to 470nH
• Current range from 23.5 to 75 Amps
• Frequency range up to 2MHz
Applications
• Multi-phase regulators
• Voltage Regulator Modules (VRMs)
• Desktop and server VRMs and EVRDs
• Notebook regulators
• Data networking and storage systems
• Graphics cards and battery power systems
• Point-of-Load modules
• DCR Sensing
Environmental Data
• Storage temperature range: -40°C to +125°C
• Operating temperature range: -40°C to +125°C
(ambient + self-temperature rise)
• Solder reflow temperature: J-STD-020D compliant
Packaging
• Supplied in tape-and-reel packaging, 700 parts per
13 inch diameter reel
Part
Number7
FP1007R6-R15-R
FP1007R6-R18-R
FP1007R6-R22-R
FP1007R6-R27-R
FP1007R6-R33-R
FP1007R6-R39-R
FP1007R6-R47-R
OCL1 ±10%
(nH)
150
180
220
270
330
390
470
FLL2 Min.
(nH)
108
129
158
194
237
280
338
Product Specifications
Irms3
(Amps)
Isat14 @25°C
(Amps)
75.0
60.0
50.0
61
41.0
33.0
28.0
23.5
Isat25 @100°C
(Amps)
60.0
50.0
40.0
33.0
26.5
22.5
19.0
DCR @20°C
(mΩ)
0.29 ± 5%
K-Factor6
348.8
1. Open Circuit Inductance (OCL) Test Parameters: 100kHz, 0.10Vrms, 0.0Adc
2. Full Load Inductance (FLL) Test Parameters: 100kHz, 0.1Vrms, Isat1
3. Irms: DC current for an approximate temperature rise of 40°C without core loss.
Derating is necessary for AC currents. PCB layout, trace thickness and width,
air-flow, and proximity of other heat generating components will affect the
temperature rise. It is recommended that the temperature of the part not
exceed 125°C under worst case operating conditions verified in the end
application.
4. Isat1: Peak current for approximately 20% rolloff at +25°C.
5. Isat2: Peak current for approximately 20% rolloff at +100°C.
6. K-factor: Used to determine Bp-p for core loss (see graph).
Bp-p = K * L * ∆I * 10-3. Bp-p:(Gauss), K: (K-factor from table),
L: (Inductance in nH), ∆I (peak-to-peak ripple current in Amps).
7. Part Number Definition: FP1007R6-Rxx-R
FP1007R6 = Product code and size
Rxx= Inductance value in uH, R = decimal point
-R suffix = RoHS compliant
0912 BU-SB12795
Page 1 of 4
Data Sheet: 10007